MCO 305 Design Guide
__ Parameter Reference __
¾
default setting
[ ]
value for use in communication via serial communication port
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
219
Par. No.
#
Parameter name
Parameter description
Default
setting
Changes
during
operation
4-set-up
Conver-
sion
index
Type
33-66
O_FUNCTION_4
Terminal X59/4 Digital
Output
[0] no function
TRUE
1 set-up
Uint8
33-67
O_FUNCTION_5
Terminal X59/5 Digital
Output
[0] no function
TRUE
1 set-up
Uint8
33-68
O_FUNCTION_6
Terminal X59/6 Digital
Output
[0] no function
TRUE
1 set-up
Uint8
33-69
O_FUNCTION_7
Terminal X59/7 Digital
Output
[0] no function
TRUE
1 set-up
Uint8
33-70
O_FUNCTION_8
Terminal X59/8 Digital
Output
[0] no function
TRUE
1 set-up
Uint8
33-8*
Global Parameters
33-80 PRGPAR
Activated Program Number
-1
TRUE
1 set-up
0
Uint8
33-81
Power-up State
Power-up State
[1] Motor on
TRUE
1 set-up
Uint8
33-82 STATUS
MONITORING
Drive Status Monitoring
[1] On
TRUE
1 set-up
0
Uint8
33-83
ERRCOND
Behavior after Error
[0] Coast
TRUE
1 set-up
Uint8
33-84
ESCCOND
Behavior after Escape
[0] Contr. Stop
TRUE
1 set-up
Uint8
33-85
EXTERNAL24V
MCO Supplied by External
24VDC
[0] No
TRUE
1 set-up
Uint8
MCO Data Readouts, Parameter List
Par. No.
#
Parameter Name
Parameter description
Default
setting
Changes
during
operation
4-Setup
Conver-
sion
Index
Type
34-0*
PCD Write Parameters
34-01
PCD 1 Write to MCO
1 set-up
Uint16
34-02
PCD 2 Write to MCO
1 set-up
Uint16
34-03
PCD 3 Write to MCO
1 set-up
Uint16
34-04
PCD 4 Write to MCO
1 set-up
Uint16
34-05
PCD 5 Write to MCO
1 set-up
Uint16
34-06
PCD 6 Write to MCO
1 set-up
Uint16
34-07
PCD 7 Write to MCO
1 set-up
Uint16
34-08
PCD 8 Write to MCO
1 set-up
Uint16
34-09
PCD 9 Write to MCO
1 set-up
Uint16
34-10
PCD 10 Write to MCO
1 set-up
Uint16
34-2*
PCD Read Parameters
34-21
PCD 1 Read from MCO
1 set-up
Uint16
34-22
PCD 2 Read from MCO
1 set-up
Uint16
34-23
PCD 3 Read from MCO
1 set-up
Uint16
34-24
PCD 4 Read from MCO
1 set-up
Uint16
Содержание MCO 305
Страница 4: ......