MCO 305 Design Guide
__ Parameter Reference __
¾
default setting
[ ]
value for use in communication via serial communication port
200
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
33-24 Marker Number for Fault
SYNCFAULT
Range
0 – 10000
¾
10
Function
Defines how often during a marker synchronization
(SYNCM and SYNCCMM) an inaccuracy may occur
during a synchronization evaluation before a FAULT
is registered.
In the program this condition can be queried using
SYNCSTAT.
33-25 Marker Number for Ready
SYNCREADY
Range
0 – 10000
¾
1
Function
SYNCREADY defines how often during a marker
synchronization (SYNCM and SYNCCMM) a synchro-
nization evaluation with ACCURACY must be
completed with accuracy so that ready is fulfilled.
ACCURACY is checked during every correction. If
ACCURACY is fulfilled then 1 is added until the set
marker number has been achieved.
Synchronization evaluation is always executed after
m marker pulses by the master par. 33-15
Marker
Number for Master
.
ACCURAY and READY can be queried using SYNCSTAT.
33-26 Velocity Filter
SYNCVFTIME
Range [Unit]
–MLONG – MLONG [
P
s]
–999 – 999 = standard table
¾
0
Standard Table
encoder resolution
W
_filt [
P
s]
250
39500
256
38600
500
19500
512
19000
1000
9500
1024
9300
2000
4500
2048
4400
2500
3500
4096
1900
5000
1400
Function
This parameter configures the velocity filter which is
used for the velocity synchronization. Since the ve-
locity synchronization only uses the currently active
master velocity and the values can decrease to very
small values (e.g. 2 qc/ms), a small fluctuation in
velocity can have dramatic effects. In order to even
this out the following filter function is applied:
Cmdvel =
Old_ (Actvel – Old_Cmdvel) * ms/
W
_filt
With the following:
Cmdvel
= set velocity
Old_Cmdvel
= last set velocity
Actvel
= actual velocity of the master
ms
= sampling time (fixed 1ms)
W
_filt
= filter time constants
Generally the value for
W
_filt is taken from a table,
depending on the Encoder counts per revolution of
the master. This value can be overwritten by the
parameter
Velocity Filter
and is always used when
Velocity Filter
is not equal zero.
If the speed filter is defined with a negative
number, the corresponding value also applies for
angle/position synchronization SYNCP and for
marker correction SYNCM.
In this case filtering takes place as described
above, but the errors made are summed up. This
error sum is taken into the calculation with
1000/(
W
*10) in each case, so that no position
deviation can occur over prolonged periods.
The value returned by SYNCERR always contains
the error made so that this is also used for the eva-
luation of the synchronicity. In the case of marker
correction the correction value is balanced more
slowly and with the same factor as the error sums.
If, for example, a filter factor of –100000 (100 ms)
is used, a marker correction is balanced within
1 second (100 ms * 10). This allows a ‘taming’ of the
synchronization without restricting the acceleration.
Содержание MCO 305