Electric Displacement Control (EDC), option A2 (12 V) / A3 (24 V)
P003 397E
Shaft L
c
Mounting flange
Shaft L
c
Connector :
Deutsch DT04-2P
to be paint free
Connector :
Deutsch DT04-2P
to be paint free
204.3 ± 2.0
[8.042 ± 0.079]
128.4 ± 2.0
[5.055 ± 0.079]
64.2 ± 1.0
[2.528 ± 0.039]
2x 178.3 ± 1.0 [7.018 ± 0.039]
2x 141.5 ± 1.0
[5.571 ± 0.039]
79.4 ± 1.0
[3.13 ± 0.039]
Case gauge port “M14”
Port ISO 11926-1 –
7
/
16
-20
∅
21 max clearance dia for fitting
209.0 max
[8.228]
Electric Displacement Control (EDC) with MOR, options A4 (12 V) / A5 (24 V)
P003 398E
Shaft L
c
Mounting flange
Shaft L
c
Connector :
Deutsch DT04-2P
to be paint free
204.3 ± 2.0
[8.042 ± 0.079]
128.4 ± 2.0
[5.055 ± 0.079]
64.2 ± 1.0
[2.528 ± 0.039]
Case gauge port “M14”
Port ISO 11926-1 –
7
/
16
-20
∅
21 max clearance dia for fitting
2x 178.3 ± 1.0 [7.018 ± 0.039]
2x 141.5 ± 1.0
[5.571 ± 0.039]
209.0 max
[8.228]
79.4 ± 1.0
[3.13 ± 0.039]
Connector :
Deutsch DT04-2P
to be paint free
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Controls
54 |
©
Danfoss | May 2017
11063346 | BC00000198en-US0801