A
G
H
J
K
M
N
S T
V
W
X
Y
Z
D
E
F
A
H1P
A B
S – Charge pump
A
26 cm³/rev [1.69 in³/rev]
L
34 cm³/rev [2.07 in³/rev]
N
No charge pump, external charge supply (
Align with options:
E and T)
T – Filtration (Align with option G – Endcap selection)
L
Suction filtration
M
Integral full charge flow filtration with bypass, bypass sensor, long filter length, 11004919
N
Integral full charge flow filtration with bypass, bypass sensor, no filter
P
Remote full charge flow filtration
E
External charge flow filtration (
Align with options:
N and S)
V – Charge pressure relief setting
18
18 bar [261 psi]
Not to be used for NFPE, AC and FDC controls.
20
20 bar [290 psi]
22
22 bar [319 psi]
24
24 bar [348 psi]
26
26 bar [377 psi]
28
28 bar [406 psi]
30
30 bar [435 psi]
32
32 bar [464 psi]
34
34 bar [493 psi]
W – Special hardware features
PN
EDC / FNR / MDC valve plate
P1
NFPE valve plate (
Align with options:
D and E)
P2
NFPE / FDC / AC valve plate and speed ring on the cylinder block
P4
EDC / FNR / MDC valve plate with speed ring on the cylinder block (
Align with options:
D and E )
H1
MDC / EDC / FNR valve plate with MDC handle
X – Paint and nametag
NNN
Black paint and Danfoss nametag
Technical Information
H1 Axial Piston Single Pumps, Size 115/130
Master Model Code
©
Danfoss | May 2017