General information
The Devidry™ floor heating system
consists of a foam/carpet heating ele-
ment with heating elements inside. The
system must always be controlled with
the Devidry™ Kit (controller and current
device – sold separately) as it is part of
the safety and overheating protections
system. The Devidry™ floor heating
system has been developed to the dry
application area for underfloor heating.
It is applicable for wooden and concrete
floor constructions with the two out-
put ranges 55W/m
2
and 100W/m
2
. Your
Devidry™ floor heating system complies
with the standard for removable floors
EN/IEC 60335-1 and EN/IEC 60335-2-106,
which specifies the maximum output for
the following floor constructions:
Wooden floor constructions:
Only 55 W/m
2
Concrete floor constructions:
55 W/m
2
or 100 W/m
2
Flooring Devidry™
Wooden floor construction
Flooring Devidry™
Concrete floor construction
The Devidry™ floor heating system can
be used under wooden floors, parquet
and laminate (and thin carpets). Please
check the specifications with your sup-
plier of these products. The insulation
value of the floor covering should not
exceed 0,1m
2
K/W. The Devidry™ floor
heating system is for indoor applications
in dry rooms only and must always be
installed with the Devidry™ Kit. If the
system is installed under carpets we
recommend to full tape the elements
together with duct tape (not supplied
in the kit). As with any other underfloor
heating system, it will be most effective
if the underfloor is well insulated. The
following directions will guide you step-
by-step through the installation process.
Please read the directions and the safety
precautions before you start the installa-
tion process.