16
08090471 - 01
Unroll and align the Devidry™ elements
where you intend to place them with the
printed side upwards. All elements have
an end stop to protect the connection
against pressure. Remove the end stops
with the special tool, just before making
the connection with the next heating
elements. If all end stops are taken out
at once, remember to leave the end stop
in the last element.
Connect the plug-in connection of the
second element into the plug-in connec-
tion of the first element. Put the male
and female connector together by hand
before using the connector tool to push
the elements tight together. Check that
the plug-in connection fits correctly and
permanently. Continue with the subse-
quent elements in the same manner.
Make sure that all plug-in connections
fit straight and without any mechani-
cal stress. Discontinue the floor heat-
ing installation process in the event of
damage to one or more components.
Incorrect installation may cause prob-
lems and/or defects to the floor heating
elements or activating the safety unit.
Make sure that the end stop in the last
element is in place before the floor
covering is laid. Keep the end stops if
you intend to remove/reposition your
floor later.
1
2
2
1
1
2
2
1
4. Connecting the Devidry™ elements