Danfoss Devidry Скачать руководство пользователя страница 23

23

08090471 - 01

INT

Safety precautions

•  Use the floor heating element for the 

purposes described in the directions 

only. 

•  Devidry™ must always be installed with 

the Devidry™ Kit.

•  Mount and connect the Devidry™ Kit to 

the mains following the correct installa-

tion instructions supplied with the Kit. 

The Devidry™ Kit is sold separately. 

•  The Devidry™ floor heating system is to 

be supplied through a residual current 

device having a rated residual operat-

ing current not exceeding 30 mA.

•  All the used Devidry™ elements must 

have the same area output.

•  The Devidry™ elements are not to be 

installed on irregular surfaces.

•  Do not fold or sharply bend the floor 

heating elements.

•  In order to avoid a fire hazard, the Devi

-

dry™ 100 is to be installed only above 

a floor of concrete or similar material. 

Devidry™ 55 can be installed on either 

concrete or wooden floors.

•  The controller Devidry™ C100 must 

only be used with installations on con-

crete floors and Devidry™ C55 can be 

used with both floor constructions.

•  Devidry™ heating element must be 

separated from other heat sources.

•  The Devidry™ heating element must 

not be installed at ambient tempera-

tures below 5°C.

•  The Devidry™ floor heating system is 

only for indoor use.

•  Do not install or use the floor heating 

system after one or more components 

have been damaged.

•  Do not allow home repairs under any 

circumstances. Repairs must be carried 

out by qualified electricians. Faulty 

repairs may cause personal injury or 

damage to property.

•  Do not use the floor heating in combi

-

nation with parts that are not recom-

mended, installed or supplied by DEVI.

•  Use original parts of the Devidry™ floor 

heating system only. The warranty for 

the entire system and for the separate 

parts becomes null and void if parts 

from other manufactures have been 

used. 

•  Make sure that no hot spots develop 

when using the floor heating system. 

Avoid hot spots by ensuring that the 

heat from the floor heating is homoge-

neously released to the area you wish 

to heat. Do not install the floor heating 

element under permanent or built-in 

cupboards (full covering furniture). 

•  Do not use the Devidry™ floor heating 

system if the system is wet.

•  Warning label should be filled out and 

placed next to the distribution switch-

board.

•  The Devidry™ floor heating system 

is only to be used with the Devidry™ 

extension cords (The Devidry™ X). Do 

never cut the extension cords or the 

output cords.

•  Do not buckle the supply cord and the 

extension cords; do not have them run 

across hot and/or sharp objects.

•  Unroll the cords entirely to prevent the 

cords from overheating.

•  Remove the plug from the wall socket 

outlet if work is carried out at or near 

the floor heating system when fluids or 

sharp objects are being used.

Содержание Devidry

Страница 1: ...Installation instruction Devidry Click Plug Floor Heating INT...

Страница 2: ...of experience We are confident that you will be satis fied with your new system DEVI brings you optimum comfort with the luxury and comfort of a warm floor as well as a pleasant room temperature Floo...

Страница 3: ...Only 55 W m2 Concrete floor constructions 55 W m2 or 100 W m2 Flooring Devidry Wooden floor construction Flooring Devidry Concrete floor construction The Devidry floor heating system can be used unde...

Страница 4: ...ement Devidry FM Devidry End Stop Product overview The Devidry Kit consists of the Devidry C controller the Devidry CD current device the Devidry Connec tion Tool and aluminium tape to fasten the floo...

Страница 5: ...5 08090471 01 INT Devidry X Devidry Tape Devidry Protection Cap...

Страница 6: ...5 Devidry Element Devidry Kit 55 Devidry Kit or Devidry 100 Devidry Element Devidry Kit 100 Devidry Kit Accessories Devidry Name Description Devidry X 25 Devidry Extension Cord 25 cm Devidry X 100 Dev...

Страница 7: ...l details of Devidry Height 8 mm Mains voltage 230 V 50 Hz Max Amps per Devidry System 10 Amp IP rating for Devidry Element IP X7 Output 55 W m2 or 100 W m2 Sound reduction value 17 dB Insulation valu...

Страница 8: ...7 watt 0 33 Amp 3 m2 2 4 m2 132 watt 0 57 Amp 4 m2 3 4 m2 187 watt 0 81 Amp 5 m2 4 4 m2 242 watt 1 05 Amp For Devidry 100 Floor area Heated surface Total power output Amp 1 m2 0 4 m2 40 watt 0 17 Amp...

Страница 9: ...nt cannot be cut here as there are electrical parts in this area EMA EUR K For indoor use only EMA EUR K Read the instruction manual before installation EMA EUR K Double insulated EMA EUR K DEVI decla...

Страница 10: ...alculation of available power supply The output cord from the control system will go into the right side of the heating element so you should start laying the first heat element on the right side of t...

Страница 11: ...A Devidry floor heating extension cord is available as an accessory Use the cord only in the event that you are unable to make a direct connection between two adjacent floor heating elements 3 When p...

Страница 12: ...ots develop when using the floor heating system Avoid hot spots by ensuring that the heat from the floor heating is homoge neously released to the area you wish to heat and that there is free space ve...

Страница 13: ...bt about which fuse covers the particular floor area you can simply turn it off and see what appliances that are not working You can typically find the power of your electric appliances imprinted as w...

Страница 14: ...nning short of power total wattage on the one fuse you will need to split the floor heating elements up into several zones Connect the second zone to a second control system thermostat and a second av...

Страница 15: ...0 Amp 2 m2 1 5 m2 77 watt 0 33 Amp 3 m2 2 5 m2 132 watt 0 57 Amp 4 m2 3 5 m2 187 watt 0 81 Amp 5 m2 4 5 m2 242 watt 1 05 Amp For Devidry 100 Floor area Heated surface Total power output Amp 1 m2 0 5 m...

Страница 16: ...or together by hand before using the connector tool to push the elements tight together Check that the plug in connection fits correctly and permanently Continue with the subse quent elements in the s...

Страница 17: ...only be cut at the far ends where there are no electrical parts inside as marked on the product below Markings and symbols have been print ed on the Devidry heating elements EMA EUR K Indicates where...

Страница 18: ...ating elements in your room is correct we suggest you make every thing fit before you secure the elements permanently It is most important to make sure that all plug in connections are perfectly align...

Страница 19: ...not to fold and or squeeze the cord between the kit and the floor heating element but make room for the cord in the filler material Minimum bending diameter is 5 cm The sensor is installed by clickin...

Страница 20: ...a tures 30 Celsius for wooden floors and 35 Celsius for concrete floor construc tions After a short while you will notice the Devidry floor heating elements are warming up Max set point temperature of...

Страница 21: ...hat is included in the Devidry Kit must be filled out and installed in the distribution board For future reference it is important to fill in which room and how many Devidry elements that have been in...

Страница 22: ...22 08090471 01 Layout paper Please draw the room on the page below and position the heating mats that you are installing for future reference These products are installed in Room...

Страница 23: ...m after one or more components have been damaged Do not allow home repairs under any circumstances Repairs must be carried out by qualified electricians Faulty repairs may cause personal injury or dam...

Страница 24: ...id a hazard Connect the floor heating to alternat ing current 230 Volt and 50 Hz only Do not allow needles sharp objects liquids and or other electricity con ducting objects fluids to make contact wit...

Страница 25: ...25 08090471 01 INT...

Страница 26: ...hip Repair or replacement shall be carried out solely at DEVI s discretion DEVI shall not be liable for any consequential or incidental damages including but not limited to damages to property or extr...

Страница 27: ...arranty certificate is granted to Name Address City Country Telephone Attention The Warranty Certificate must be completed correctly for the Warranty to be valid Please read the Warranty conditions on...

Страница 28: ...08090471 Version 01 DEVI A S Ulvehavevej 61 DK 7100 Vejle Tel 45 7642 4700 Fax 45 7642 4701 www devi com 08090471 01 01 VIEDA202 09 2012...

Отзывы: