35
13 - OPTIONS
Options
No.
Description
Advantages
Use
Soft starter
25
Electronic compressor starter
Reduced compressor start-up current
BW10 020-090
Twinning
58
Unit equipped with an additional field-installed
leaving water temperature sensor, allowing master/
slave operation of two units connected in parallel.
Optimised operation of two units connected
in parallel with operating time equalisation
BW10 020-090
External disconnect handle
70F
The handle of the electrical disconnect switch is on
the outside of the unit
Quick access to the unit disconnect switch
BW10 020-090
Condenser insulation
86
Thermal condenser insulation
Optimisation for heating applications
BW10 020-090
Low-pressure single-pump hydronic module,
evaporator side
116F See hydronic module chapter
Easy and fast installation
BW10 020-090
High-pressure single-pump hydronic module,
evaporator side
116J
See hydronic module chapter
Easy and fast installation, reduced power
consumption of the water circulation pump.
BW10 020-090
JBus gateway
148B Two-directional communications board, complies
with JBus protocol
Easy connection by communication bus to a
building management system
BW10 020-090
BacNet gateway
148C Two-directional communications board, complies
with BacNet protocol
Easy connection by communication bus to a
building management system
BW10 020-090
LON gateway
148D Two-directional communications board, complies
with LON protocol
Easy connection by communication bus to a
building management system
BW10 020-090
Specific single-source heating control
153
Control board factory-installed on the unit, control
using weather compensation, control of supplemen-
tary electric heater (4 stages) or boiler, needle valve
for domestic hot-water production with
programmable time schedule.
Permits easy control of a basic heating
system
BW10 020-090
Specific cooling control
154
Control box to be installed on the drycooler for
communication with the unit via a bus.
Permits the use of an energy-efficient
plug-and-play system
Control of multi-source heating system
157
Additional control box for remote installation to
control the various heating system components
Allows control of pre-configured heating
systems
BW10 020-090
Low sound level (-3 dB(A) compared to standard
unit)
257
Compressor sound insulation
BW10 020-090
Evaporator screw connection sleeves
264
Evaporator inlet/outlet screw connection sleeves
Allows unit connection to a screw connector
BW10 020-090
Screw water connection between the customer
condenser and the unit
265
Condenser inlet/outlet screw connection sleeves
Allows unit connection to a screw connector
BW10 020-090
Welded evaporator connection sleeves
266
Welded evaporator inlet/outlet connection sleeves
Allows welding of customer connections to
the unit
BW10 020-090
Welded water connection between the customer
condenser and the unit
267
Welded condenser inlet/outlet connection sleeves
Allows welding of customer connections to
the unit
BW10 020-090
Low-pressure single-pump hydronic module,
condenser side
270F See hydronic module chapter
Easy and fast installation
BW10 020-090
High-pressure hydronic module with single
variabe-speed pump, condenser side
270J
See hydronic module chapter
Easy and fast installation, reduced power
consumption of the water circulation pump.
BW10 020-090
High-temperature water production, condenser
side, with glycol solution on the evaporator side
272
Condenser side water production up to 65°C, with
glycol solution on the evaporator side to -5°C
Geothermal application and domestic
hot-water production
BW10 020-090
Unit stackable for operation
273
Unit stackable for operation
Reduced footprint size
BW10 020-090
Customer water connection at the top of the unit
274
Customer water connection at the top of the unit
Reduced footprint size
BW10 020-090
Remote user interface
275
User interface for remote installation
Remote control of the unit and its operating
parameters
BW10 020-090