ET3000-TA Operating Instructions
1. Open vent plug on reservoir before operation.
Release the pusher clip and slide pusher back. Note:
periodically lubricate the die ring with Danfoss
T-400-G lubricant. When crimping with Danfoss
tooling insert the T-420-25 adapter die ring into the
base plate. Insert the proper sized collet.
3. Loosen knob and tilt press as necessary. Insert hose
assembly from below the base plate and between
the collet halves. Align crimp scribe line on end
fitting with top of collet, making sure that collet
halves are evenly matched.
5. Attach air supply and depress pressure end of treadle
and hold until spacer ring contacts the base ring
indicating that the crimp is complete.
2. Select the proper Aeroquip hose and end fitting.
Insert the hose into the end fitting making sure
that the hose is bottomed into the end fitting. For
insertion depth information, reference figure on
page 12.
4. Holding uncrimped hose assembly in place, reference Hose End and
Tool Selector Chart found in Product Advisor for correct spacer ring.
Note: when crimping hose that does not require a stepped spacer ring,
the T-480 -68 pusher extension must be used to prevent damage to the
pusher. Position spacer ring on top of collet with proper side of spacer
ring facing up as shown on page 13 and slide pusher forward, making
sure pusher clip has locked.
6. Depress the release end of treadle to retract pusher. Release the pusher
clip and slide the pusher back to access tooling. Remove the spacer
ring and the crimped hose assembly from below the base plate and
between the collet halves. Note: visually inspect the crimped end.
Check nominal crimp diameter and verify that the crimp is within
specification on Page 14.