Aeroquip ET3000 Portable Crimp System Set-up and Operating Instructions
14 | © Aeroquip ET3000 Portable Crimp System Set-up and Operating Instructions | 2022.10.
BC425481899278en-000101
How to Measure Crimp Diameters
Crimp Diameter
Measurement Locations
Crimp Diameter
Crimp Ovality
Crimp Ovality
Crimp Diameter
= 31,62mm (1.245in)
=
=
Diameter measurements are to be
taken at the center (top to bottom,
side to side) of the specified fitting
section.
Note:
The example and drawing
on this page show an Aeroquip
MatchMate Plus fitting.
The crimp diameter is the
average of the four diameter
measurements around the fitting.
These measurements are to be
taken at the same relative locations
indicated in the illustration above.
Crimp ovality is the largest diameter
measurement minus the smallest
diameter measurement.
Example
GH781-12 hose with a 1AA12FJ12 fitting measures:
Measurement 1 =
31,57mm (1.243 in.)
Measurement 2 =
31,60mm (1.244 in.)
Measurement 3 =
31,65mm (1.246 in.)
Measurement 4 =
31,65mm (1.246 in.)
Measurement 1 + Measurement 2 + Measurement 3 + Measurement 4 = Crimp Diameter
31,51mm (1.243in) + 31,60mm (1.244in) + 31.65mm (1.246in) + 31.65mm (1.246in)
31.65mm (1.246in) – 31.57mm (1.243in) =
0,08mm (0.003in)
4
4
Note:
Danfoss defines the crimp
diameter as the average of four
measurements, not just one
measurement (see the “End View”
illustration above).
Crimp Diameter Measurement Location