Aeroquip ET3000 Portable Crimp System Set-up and Operating Instructions
9 | © Aeroquip ET3000 Portable Crimp System Set-up and Operating Instructions | 2022.10.
BC425481899278en-000101
ET3000-AH Set-Up & Operating Instructions
1. Pump reservoir must be properly vented before
operation. Release the pusher clip and slide pusher
back. Note: periodically lubricate the die ring with
Danfoss T-400-G lubricant. When crimping with
Danfoss tooling insert the T-420-25 adapter die ring
into the base plate. Insert the proper sized collet.
3. Loosen knob and tilt press as necessary. Insert hose
assembly from below the base plate and between
the collet halves. Align crimp scribe line on end
fitting with top of collet, making sure that collect
halves are evenly matched.
5. Attach air supply and depress pressure valve and
hold until spacer ring contacts the base ring,
indicating that the crimp is complete.
2. Select the proper Aeroquip hose and end fitting.
Insert the hose into the end fitting making sure
that the hose is bottomed into the end fitting. For
insertion depth information, reference figure on
page 12.
4. Holding uncrimped hose assembly in place, reference Hose End and
Tool Selector Chart found in Product Advisor for correct spacer ring.
Note: when crimping hose that does not require a stepped spacer ring,
the T-480 -68 pusher extension must be used to prevent damage to the
pusher. Position spacer ring on top of collet with proper side of spacer
ring facing up as shown on page 13 and slide pusher forward, making
sure pusher clip has locked.
6. Release pressure valve to retract pusher. Release the pusher clip and
slide the pusher back to access tooling. Remove the spacer ring and
the crimped hose assembly from below the base plate and between
the collet halves. Note: visually inspect the crimped end. Check nominal
crimp diameter and verify that the crimp is within specification see
Page 14.