Aeroquip ET3000 Portable Crimp System Set-up and Operating Instructions
12 | © Aeroquip ET3000 Portable Crimp System Set-up and Operating Instructions | 2022.10.
BC425481899278en-000101
Hose Preparation Instructions
TTC and TTC12 Crimp Style Fittings
Select a matching hose and fitting
combination from the current
Aeroquip Master Hose Assembly
Catalog.
Step 1: Cut the Hose
Cut the hose squarely and to the
proper length using a suitable cut
off saw. The cut angle must not
exceed 5°. Read the saw operation
manual for cutting instructions and
blade applications.
Step 4: Crimp the Fitting
Crimp the fitting then measure the
crimp diameter, ovality dimension
and inspect the nipple/socket
position.
Step 2: Clean the Hose
Bore
Use the Danfoss FT1455 hose
cleaning system to, flush
contaminants from the hose bore.
Follow shop safety rules.
Step 5: Plug or cap the
hose end fittings as required.
Step 3: TTC,TTC12: Insert the
Fitting into the Hose
To determine the fitting insertion
depth, use the appropriate FF90308
hose insertion gage or align the
end of the hose with the scribe line
(located on socket taper) and mark
the hose where the gage or socket
ends. Insert the fitting into the hose
until the bottom of the socket is
aligned with the mark on the hose
or it bottoms out.