PRELIMINARY
Spyder3 GigE User Manual
03-032-10158-04
DALSA
102
Mnemonic
Syntax Parameters Description
set video mode
svm
i
Switch between normal video mode
and camera test patterns:
0
: Normal video mode
1
: Camera test pattern
2
: Camera test pattern
update gain reference
ugr
Changes 0dB gain to equal the current
analog gain value set with the
sag
command.
verify temperature
vt
Check the internal temperature of the
camera
verify voltage
vv
Check the camera’s input voltages and
return OK or fail
write FPN coefficients
wfc
i
Write all current FPN coefficients to
EEROM where
i
is:
1
= FPN coefficient set one
2
= FPN coefficient set two
3
= FPN coefficient set one
4
= FPN coefficient set two
write PRNU coeffs
wpc
i
Write all current PRNU coefficients to
EEROM where
i
is:
1
= PRNU coefficient set one
2
= PRNU coefficient set two
3
= PRNU coefficient set one
4
= PRNU coefficient set two
write user settings
wus
Write all of the user settings to EEROM.
A5 Error Handling
The following table lists warning and error messages and provides a description and
possible cause. Warning messages are returned when the camera cannot meet the full
value of the request; error messages are returned when the camera is unable to complete
the request.
Table 15: Warning and Error Messages
Message
Description
OK>
SUCCESS
Warning 01: Outside
of specification>
Parameter accepted was outside of specified operating range (e.g. gain
greater than ±10 dB of factory setting).
Warning 02: Clipped
to min>
Parameter was clipped to the current operating range. Use
gcp
to see
value used.
Warning 03: Clipped
to max>
Parameter was clipped to the current operating range. Use
gcp
to see
value used.
Warning 04: Related
parameters
adjusted>
Parameter was clipped to the current operating range. Use
gcp
to see
value used.
Содержание spyder SG-10-01k80
Страница 16: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 16...
Страница 30: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 30...
Страница 45: ...Spyder3 GigE User s Manual PRELIMINARY DALSA 03 032 10158 04 45...
Страница 104: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 104...
Страница 106: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 106...
Страница 109: ...Spyder3 GigE User s Manual PRELIMINARY DALSA 03 032 10158 04 109...