PRELIMINARY
Spyder3 GigE User Manual
03-032-10158-04
DALSA
76
Setting Digital System Gain
Purpose:
Improves signal output swing after a background subtract. When
subtracting a digital value from the digital video signal, using the
101H
ssb
command, the output can no longer reach its maximum. Use
this command to correct for this where:
ssg
value
=
max
output
value
max
output
value
‐
ssb
value
Syntax:
ssg t i
Syntax Elements:
t
Tap selection. Allowable range is
1
to
2
, or
0
for all taps.
i
Gain setting. The gain ranges are
0
to
65535
. The digital
video values are multiplied by this value where:
Use this command in conjunction with the
102H
ssb
command.
Related Commands:
103H
ssb
Example:
ssg 1 15
Returning Calibration Results and Errors
Returning All Pixel Coefficients
Purpose:
Returns all the current pixel coefficients in the order FPN, PRNU,
FPN, PRNU… for the range specified by
x1
and
x2
. The camera
also returns the pixel number with every fifth coefficient.
Syntax:
dpc x1 x2
Syntax Elements:
x1
Start pixel to display in a range from
1
to
sensor pixel
count
.
x2
End pixel to display in a range from
x1
to
sensor pixel
count
.
Notes:
This function returns all the current pixel coefficients in the
order FPN, PRNU, FPN, PRNU… The camera also returns the
pixel number with each coefficient.
Example:
dpc 10 20
Digital
Gain=
4096
i
Содержание spyder SG-10-01k80
Страница 16: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 16...
Страница 30: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 30...
Страница 45: ...Spyder3 GigE User s Manual PRELIMINARY DALSA 03 032 10158 04 45...
Страница 104: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 104...
Страница 106: ...PRELIMINARY Spyder3 GigE User Manual 03 032 10158 04 DALSA 106...
Страница 109: ...Spyder3 GigE User s Manual PRELIMINARY DALSA 03 032 10158 04 109...