Region of Interest:
(1,1) to (12288, 1)
Region of interest size set
with the
roi
command.
See section 3.4.1 Setting a
Region of Interest (ROI)
for details.
End-Of-Line Sequence:
on
States whether an end of
line sequence is turned on
or off. Set using the
els
command. See section
3.4.3 End-of-line Sequence
for details.
FFC Coefficient Set:
0
Current pixel coefficient
set loaded. Refer to
section 3.5.1 Saving and
Restoring PRNU and FPN
Coefficients for details.
FPN Coefficients:
off
States whether FPN
coefficients are on or off.
Set with the
epc
command. Refer to section
3.4.2 Analog and Digital
Signal Processing Chain
for details.
PRNU Coefficients:
off
States whether PRNU
coefficients are on or off.
Set with the
epc
command. Refer to section
3.4.2 Analog and Digital
Signal Processing Chain
for details.
Number of Line Samples: 256
Number of lines samples
set with the
css
command. See section
3.6.2 Returning Video
Information for details.
Upper Threshold
0
Upper threshold value set
with the
sut
command.
See section 3.4.3 End-of-
line Sequence for details.
Lower Threshold
4095
Lower threshold value set
with the
slt
command.
See section 3.4.3 End-of-
line Sequence for details.
Camera Link Mode:
21, Full, 8 taps, 8
bits, no time MUX
Camera Link mode set
with the
clm
command.
See section 3.3.1 Setting
the Camera Link Mode for
details.
Содержание Piranha3
Страница 6: ...Piranha 3 User Manual 03 032 10216 02 DALSA 6...
Страница 14: ...Piranha 3 User Manual 03 032 10216 02 DALSA 14...
Страница 22: ...Piranha 3 User Manual 03 032 10216 02 DALSA 22...
Страница 74: ...Piranha 3 User Manual 03 032 10216 02 DALSA 74...
Страница 86: ...Piranha 3 User Manual 03 032 10216 02 DALSA 86 This Declaration corresponds to EN 45 014...
Страница 88: ...Piranha 3 User Manual 03 032 10216 02 DALSA 88...