Mode 4: Smart EXSYNC, External Line Rate and Exposure Time
In this mode, EXSYNC sets both the line period and the exposure time. The rising edge of
EXSYNC marks the beginning of the exposure and the falling edge initiates readout.
Example 3: Trigger Period is Repetitive and Greater than Read Out Time.
Exposure Time
CR
Exposure Time
Readout
Line Period
Line Period
EXSYNC
CR
Readout
Mode 5: External Line Rate (EXSYNC) and External Pixel Reset (PRIN)
In this mode, the falling edge of EXSYNC sets the line period and the rising edge of PRIN
sets the start of exposure time.
Figure 9: EXSYNC controls Line Period and PRIN controls Exposure Time
Mode 6: External Line Rate and Internally Programmable Exposure Time
Figure 10: EXSYNC controls Line Period with Internally controlled Exposure Time
Readout
EXSYNC
Line Period
cr=Charge Reset
Readout
PRIN
Line Period
Line Period
Readout
EXSYNC
Line Period
CR=Charge Reset
Readout
Line Period
Programmable Period
Using Command
set
Programmable Period
Using command
set