2.2 Input/Output Connectors and LED
The camera uses:
•
A diagnostic LED for monitoring the camera. See LED Status Indicator in section 2.2.1
LED Status Indicator for details.
•
Two high-density 26-pin MDR26 connectors for Camera Link control signals, data
signals, and serial communications. Refer to section 2.2.2 Camera Link
•
Data Connector for details.
•
One 6-pin Hirose connector for power. Refer to section 2.2.3 Power Connector for
details.
Figure 6: Input and Output
Camera Link (Base Configuration)
Camera Link (Medium Configuration)
Diagnostic LED
+12V to +15V
CONTROL
DATA 1
DATA 2
POWER
WARNING: Ensure that all the correct voltages at full load are present at the camera end of the
power (irrespective of cable length) according to the pinout defined in section 2.2.3 Power
Connector.
2.2.1 LED Status Indicator
The camera is equipped with a red/green LED used to display the operational status of
the camera. The table below summarizes the operating states of the camera and the
corresponding LED states.
When more than one condition is active, the LED indicates the condition with the highest
priority. Error and warning states are accompanied by corresponding messages further
describing the current camera status.
Status LED
Color of Status LED Meaning
Flashing Green
Camera initialization or executing a time consuming command
Solid Green
Camera is operational and functioning correctly
Flashing Red
Fatal Error. System voltage out of tolerance.
Solid Red
Warning. Loss of functionality (e.g. external SRAM failure)