Falcon 4M Camera Manual
DALSA 03-032-20044-01
17
Camera Link Connector Pinout
Medium Configuration
Base Configuration
Up to an additional 2 Channel Link Chips One Channel Link Chip + Camera
C Serial Communication
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
Camera
Connector
Right Angle
Frame
Grabber
Connector
Channel
Link Signal
1
1
inner shield
1
1
inner shield
14
14
inner shield
14
14
inner shield
2
25
Y0-
2
25
X0-
15 12
Y0+
15
12 X0+
3
24
Y1-
3
24
X1-
16 11
Y1+
16
11 X1+
4
23
Y2-
4
23
X2-
17 10
Y2+
17
10 X2+
5
22
Yclk-
5
22
Xclk-
18
9
Yclk+
18 9 Xclk+
6
21
Y3-
6
21
X3-
19
8
Y3+
19 8 X3+
7
20
100 ohm
7
20
SerTC+
20
7
terminated
20 7 SerTC-
8
19
Z0-
8
19
SerTFG-
21
6
Z0+
21 6
9
18
Z1-
9
18
CC1-
22
5
Z1+
22 5 CC1+
10
17
Z2-
10
17
CC2+
23
4
Z2+
23 4 CC2-
11
16
Zclk-
11
16
CC3-
24
3
Zclk+
24 3 CC3+
12
15
Z3-
12
15
CC4+
25
2
Z3+
25 2 CC4-
13
13
inner shield
13
13
inner shield
26
26
inner shield
26
26
inner shield
Notes:
*Exterior Overshield is connected to the shells of the connectors on both ends.
**3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.
Unused pairs should be terminated in 100 ohms at both ends of the cable.
Inner shield is connected to signal ground inside camera
DALSA Camera Control Configuration
Signal
Configuration
CC1 EXSYNC
CC2
Reserved for future use
CC3
Reserved for future use
CC4
Window toggle
Содержание Falcon 4M30
Страница 63: ...Falcon 4M Camera Manual DALSA 03 032 20044 01 63 ...
Страница 71: ...Falcon 4M Camera Manual DALSA 03 032 20044 01 71 Note User EXSYNC not present in sem 2 ...
Страница 81: ...Falcon 4M Camera Manual DALSA 03 032 20044 01 81 ...
Страница 83: ...Falcon 4M Camera Manual DALSA 03 032 20044 01 83 ...