Falcon 4M Camera Manual
DALSA 03-032-20044-01
75
Command
Syntax Parameters
Description
coefficient set
number
csn
i
Selects the coefficient set to use:
0-7
= Factory calibrated sets of FPN
and PRNU coefficients. These
coefficients cannot be erased or
modified.
8-15
= User calibrated sets of FPN and
PRNU coefficients. These coefficients
can
be deleted or modified.
CSN
EFD
0, 8
1
1, 9
0
2, 10
2
3, 11
1
4, 12
0
5, 13
2
6, 14
All coefficients = 0
7, 15
FPN/PRNU Test Pattern
calibration sample
size
css m
Sets the number of lines to sample
when performing FPN and PRNU
calibration where
m
is
32
,
64
,
128
(factory setting),
256
,
512
, or
1024
display pixel
coefficients
dpc x1y1
x2y2
Displays the pixels coefficients in the
order FPN, PRNU, FPN, PRNU…
x1y1 = pixel start address
x2y2 = pixel end address
in the range from 1, 1 to 2352, 1728.
enable debounce
circuit
edc m
When enabled (EDC 1) filters EXSYNC
from the user to suppress any glitches
less than 1us in width.
enable frame dump
efd m
Enables various snapshot modes
EFD 0 – snapshot mode disabled
EFD 1 – snapshot mode 1, FFD on
falling edge of EXSYNC
EFD 2 – snapshot mode 2, FFD on rising
edge of EXSYNC
enable pixel
coefficients
epc i
i
Enables or disables FPN and PRNU
coefficients.
The first parameter sets the FPN
coefficients where
i
is:
0
= FPN coefficients disabled
1
= FPN coefficients enabled
The second parameter sets the PRNU
coefficients where
i
is:
0
= PRNU coefficients disabled
1
= PRNU coefficients enabled
get camera model
gcm
Read the camera model number.
get camera
parameters
gcp
Read all of the camera parameters.
Parameters:
t
= tap id
i
= integer value
f
= real number
s
= string
m
= member of a
set
Содержание Falcon 4M30