![background image](http://html1.mh-extra.com/html/dallmeier/domera-ddz3018-im-hs/domera-ddz3018-im-hs_installation-and-configuration-manual_3347450084.webp)
www.dallmeier.com
84
DDZ30XX-YY/HS/IP
14.3.5
Actions
ACTION SETUP
Alarm Action
Alarm List
Clear Alarm List
Schedule Action
Schedule Action List
Exit
Alarm Action
Not available at IP based operation
Alarm List
Not effective at IP based operation
Clear Alarm List
Not effective at IP based operation
14.3.5.1 Alarm Actions
The
ALARM ACTION SETUP
is not available at IP based operation.
ALARM ACTION SETUP
NO FUN PRI IN OUT HLD LATCH
01 --- 1 OFF OFF 003 OFF
02 --- 1 OFF OFF 003 OFF
03 --- 1 OFF OFF 003 OFF
04 --- 1 OFF OFF 003 OFF
05 --- 1 OFF OFF 003 OFF
06 --- 1 OFF OFF 003 OFF
07 --- 1 OFF OFF 003 OFF
08 --- 1 OFF OFF 003 OFF
Dwell :03 SEC
Save and Exit
NO
Alarm input number
FUN
(Function)
Stored function number to be called by alarm.
PRI
(Priority)
The lower number (
0
–
8
) has higher priority.
IN
NO
(Normally Open)
NC
(Normally Closed)
OFF
: Ignore
OUT
R01
: Relay out 1
R02
: Relay out 2
OFF
: No output
HLD
(HOLD)
Alarm will be held for programmed time (
001
to
255
seconds)