![background image](http://html1.mh-extra.com/html/dallmeier/domera-ddz3018-im-hs/domera-ddz3018-im-hs_installation-and-configuration-manual_3347450080.webp)
www.dallmeier.com
80
DDZ30XX-YY/HS/IP
14.3.2
Scan
The scan function enables the PTZ dome camera to move automatically between two
user-defined positions at different speeds. This is very helpful if monitoring certain areas
frequently.
Scans may be assigned to actions or applied as “home” position.
SCAN SETUP
Number :01
Title :SCAN1
Mode :Normal
Speed :3 LEVEL
Start :None
End :None
Dir :CW
Swap :OFF
Dwell :03 Sec
Save and Exit
Number
01
–
16
Title
Up to 16 characters
Mode
Normal
:
Move from start point to end point in panning only
Diagonal
: Move from start point to end point including tilt and zoom simul-
taneously and linearly
Speed
1
–
8 Level
(
1
: slower,
8
: faster)
Dir
Scan direction:
CCW
(Counter Clock Wise),
CW
(Clock Wise)
Swap
Swaps the start point for the end point if enabled (
ON
)
Dwell
Dwell time at the start and end point,
03
–
99
seconds
Select the
Number
of the scan.
Edit the
Title
of the scan
(see section “
Edit Title
” on page 76).
Select the scan
Mode
.
Select the scan
Speed
.
Edit the position of the
Start
and
End
point
(see section “
Edit Position
” on page 77).
Edit the scan direction (
Dir
).
Set the
Swap
option.
Edit the
Dwell
time.
Execute
Save and Exit
.
To run a stored scan, go to the
Run Function
in the main
DOME MENU
.