Adjustment for lenses with a variable focal distance (zoom)
If the focus changes as the focal distance changes, please proceed as follows:
1 Point the camera at an object with sufficient contrast at a distance of approx. 2 m.
2 Open the iris on the lens.
3 Set the maximum focal distance (tele end) at the lens.
4 Set the optimum focus with the focus ring.
5 Set the smallest focal distance (wide end).
6 Loosen the locking screw (B) on the camera with an adequate Allen wrench.
7 Turn the back focus adjustment ring (D) until the optimum focus is achieved.
You may need to repeat steps 3, 4, 5, and 7 several times to obtain the best results.
8 Tighten the locking screw (B).
6.4
Installation and commissioning
The camera has a ¼’’ tripod socket located on the top and bottom side.
IMPORTANT
Possible damage to the camera caused by inappropriate
mounting equipment.
The length of the tripod screw must not exceed 7 mm.
IMPORTANT
Possible damage to the camera caused by incorrect installation.
Pay attention to the manufacturer’s documentation when
installing the camera into a weather-proof housing.
CAUTION
Danger of injury from camera falling down!
Before initial startup, ensure that the camera is securely
mounted.
¾
Mount the camera on a wall/ceiling bracket or on a pan/tilt head etc. using the ¼’’ tripod
socket (C) and an appropriate tripod screw.
¾
Connect the camera via LAN port (J) to the network.
¾
The camera can be aligned via CVBS monitor. For this purpose connect the delivered
adapter cable to the analogue video preview output (H).
WARNING
Danger of death from electric shock!
Disconnect the power supply unit from the mains socket before
connecting the camera.