![Dallas DS87C550 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/dallas/ds87c550/ds87c550_user-manual-supplement_3298646012.webp)
DS87C550 High-Speed Microcontroller User’s Guide Supplement
12 of 93
Timer/Counter Control (TCON)
7
6
5
4
3
2
1
0
SFR 88h
TF1
TR1
TF0
TR0
IE1
IT1
IE0
IT0
RW-0
RW-0
RW-0
RW-0
RW-0
RW-0
RW-0
RW-0
R=Unrestricted Read, W=Unrestricted Write, -n=Value after Reset
TF1
Bit 7
Timer 1 Overflow Flag.
This bit indicates when Timer 1 overflows its
maximum count as defined by the current mode. This bit can be cleared by
software and is automatically cleared when the CPU vectors to the Timer 1
interrupt service routine.
0 = No Timer 1 overflow has been detected.
1 = Timer 1 has overflowed its maximum count.
TR1
Bit 6
Timer 1 Run Control.
This bit enables/disables the operation of Timer 1.
0 = Timer 1 is halted.
1 = Timer 1 is enabled.
TF0
Bit 5
Timer 0 Overflow Flag.
This bit indicates when Timer 0 overflows its
maximum count as defined by the current mode. This bit can be cleared by
software and is automatically cleared when the CPU vectors to the Timer 0
interrupt service routine or by software.
0 = No Timer 0 overflow has been detected.
1 = Timer 0 has overflowed its maximum count.
TR0
Bit 4
Timer 0 Run Control.
This bit enables/disables the operation of Timer 0.
Halting this timer will preserve the current count in THO and TL0.
0 = Timer 0 is halted.
1 = Timer 0 is enabled.
IE1
Bit 3
Interrupt 1 Edge Detect.
This bit is set when an edge/level of the type defined
by IT1 is detected. If IT1=1, this bit will remain set until cleared in software or
the start of the External Interrupt 1 service routine. If IT1=0, this bit will
inversely reflect the state of the
INT1
pin.
IT1
Bit 2
Interrupt 1 Type Select.
This bit selects whether the
INT1
pin will detect edge
or level triggered interrupts.
0 =
INT1
is level triggered.
1 =
INT1
is edge triggered.
IE0
Bit 1
Interrupt 0 Edge Detect.
This bit is set when an edge/level of the type defined
by IT0 is detected. If IT0=1, this bit will remain set until cleared in software or
the start of the External Interrupt 0 service routine. If IT0=0, this bit will
inversely reflect the state of the
0
INT
pin
IT0
Bit 0
Interrupt 0 Type Select.
This bit selects whether the
0
INT
pin will detect edge
or level triggered interrupts.
0 =
0
INT
is level triggered.
1 =
0