Diagram 8K
Amplifier Signal Flow Schematic
Analog 3
Output
Matrix
Zones A - B
Outputs 1 - 2
Analog 2
Input
Sensitivity
Analog 1
Input
Gain
Input
Sensitivity
Input
Gain
Input
Sensitivity
Input
Gain
Analog 4
SPDIF (stereo)
SPDIF Out (stereo).
Zones A (left) and B (right)
Pink Noise
Gain
Level
Adjustment
Level
Adjustment
Compressor
Compressor
Delay
Delay
EQ
EQ
EQ
EQ
FIR
FIR
Polarity
Polarity
BTL
Amplifier
2 x Low-Z
1 x Hi-Z
Limiter
Limiter
Driver
Alignment
Driver
Alignment
Crossover
Crossover
Gain Trim
Gain Trim
Input
Sensitivity
Input
Gain
Input
Gain
Input
Selection
Input Setup
Zone Setup & Routing
Output Setup
Output 1
Output 2
Zone Adjustment Parameters
Speaker Preset Parameters
8.6 Setup and Signal Routing
Thanks to the DALI PHANTOM CI AMP
CONFIGURATOR the AMP-2500 DSP amplifier offers
considerable versatility in terms of sources, signal
routing, installation zones and output modes. Inputs can
be freely assigned to installation zones, and those zones
assigned freely to the available amplifier outputs in either
Lo-Z or Hi-Z modes.
This versatility enables, for example, different inputs to be
routed to different output zones.
The following paragraphs describe and illustrate the
recommended procedure for configuring input, zone and
output routing. A general signal flow schematic is also
illustrated in
Diagram 8K.
8.7 Input Setup
Open the configuration Dashboard and select the
[Input]
Tab
. The
[Input] Tab
is shown in
Diagram 8B.
•
To edit default input names simply select and type in the
Input Name field.
•
Define a mono or stereo input by selecting the
appropriate option. Defining a stereo input will reduce
the total number of discrete inputs available.
•
Select an input sensitivity option from the
[Sensitivity] drop-down menu: +14dB, +4dB, -10dB
and “[Microphone]” options are available. Generally,
the +14dB or +4dB options are appropriate for
“professional audio” source hardware with balanced
outputs, while the -10dB option is more appropriate
for “consumer audio” source hardware with
unbalanced outputs. The [Microphone] option provides
the significantly greater sensitivity required for
microphones.
NOTE
Only dynamic microphones are suitable for connection.
Phantom power for condenser microphones is not
provided.
•
If necessary, adjust the input gain using the slider or
up/down icons. Gain adjustment is intended to be used
for fine output level adjustment following initial use.