MOUNTING INSTRUCTIONS:
1. USING THE BACKUP CHANNEL AS A TEMPLATE, DRILL 9/16" HOLES IN THE UPPER AND LOWER
REAR FLANGE OF THE AD PANEL WHERE THE VERTICAL BEAMS WILL BE LOCATED.
2. IF AD PANEL HAS BACKSHEETS, REMOVE BACKSHEETS NECESSARY AT THIS TIME TO ACCESS
HARDWARE FOR UNISTRUT ATTACHMENT
3. ATTACH UNISTRUT TO AD PANEL THROUGH HOLES DRILLED IN STEP 1 AS SHOWN IN UNISTRUT
ATTACHMENT SIDE VIEW
4. REPLACE BACKSHEETS REMOVED IN STEP 2
5. PLACE SPRING NUTS INTO UNISTRUT IN APPROXIMATE LOCATION OF VERTICAL BEAMS
7. LIFT AD PANEL INTO POSITION
8. ATTACH I-BEAM CLAMPS WITH 1/2" HARDWARE AS SHOWN IN TOP AND REAR ISOMETRIC VIEW
AD PANEL ATTACHMENT
9. MAKE SURE THE 1/2-13 BOLTS ARE AS CLOSE TO THE I-BEAM FLANGES AS POSSIBLE
10. WHEN AD PANEL IS ADJUSTED TO FINAL DESIRED POSITION, TIGHTEN BOLTS FIRMLY
STRUCTURAL NOTES:
ALLOWABLE LOADS PER COLUMN CONNECTION
MAX ALLOWABLE WIND LOAD: 2,400 LBS
MAX ALLOWABLE PANEL WEIGHT: 158 LBS
COEFFICIENT OF FRICTION: 0.03
BOLT TORQUE: 50 FT-LB
MIN-MAX I-BEAM FLANGE THICKNESS: 0.25"-0.75"
***CRITICAL***
DO NOT USE ANY LUBRICANT
ON ANY MOUNTING HARDWARE
OR WARRANTY WILL BE VOIDED
1/2-13 X 3.000 BOLT
1/2" LOCK WASHER
1/2" FLAT WASHER
VERTICAL BEAM
I-BEAM CLAMP
SPRING NUT
FRONT OF AD PANEL
TOP VIEW
AD PANEL ATTACHMENT
SCALE 1/5
USE PROVIDED HOLES
TO ATTACH BACKUP
CHANNEL/UNISTRUT
TO AD PANEL
AD PANEL
SIDE VIEW
AD PANEL ATTACHMENT
SCALE 1/5
AD PANEL
I-BEAM CLAMP
SPRING NUT
UNISTRUT
VERTICAL BEAM
1/2-13 X 3.000 BOLT
1/2" LOCK WASHER
1/2" FLAT WASHER
EXPLODED SIDE VIEW
UNISTRUT ATTACHMENT
SCALE 1/10
1/2-16 X 1.500 BOLT
(LOCATED INSIDE UNISTRUT)
1/2" LOCK WASHER
(LOCATED INSIDE UNISTRUT)
1/2" FLAT WASHER
(LOCATED INSIDE UNISTRUT)
3-1/4" UNISTRUT
BACKUP CHANNEL
1/2-13 SQUARE NUT
SEE DETAIL A
EXPLODED REAR ROTATED VIEW
AD PANEL ATTACHMENT
SCALE 1/8
3-1/4" UNISTRUT
I-BEAM CLAMP
1/2-13 X 3.000 BOLT
1/2" LOCK WASHER
1/2" FLAT WASHER
SPRING NUT
***CRITICAL***
MAKE SURE SPRING NUT
IS TURNED TO VERTICAL
POSITION INSIDE
UNISTRUT CHANNEL
DETAIL A
SCALE 1/3
RECOMMENDED METHOD OF INSTALLATION:
- INSTALL 1 1/2" BOLT, 1/2" LOCK WASHER, 1/2" FLAT WASHER
USING SHALLOW SOCKET WITH EXTENSION.
- ENTER FROM SIDE OF UNISTRUT SECURING INSIDE BOLTS
FIRST AND MOVING OUTWARD
PPaarrtt ## -- 00AA--11009911--11995544
VVeerrssiioonn -- 0000..88
D
Deessccrriippttiioonn -- LLVVXX II--BBEEAAM
M M
MTTG
G;; O
OU
UTTD
DO
OO
OR
R AAD
D PPAAN
NEELL,, 44 C
CO
ON
NN
NEEC
CTTIIO
ON
NSS
LLiiffeeccyyccllee SSttaattee -- FFuullll PPrroodduuccttiioonn
LLaasstt M
Mooddiiffiieedd BByy -- kkddrraaggtt
LLaasstt M
Mooddiiffiieedd -- 22001188--0066--2222
Содержание FB-2700 Series
Страница 38: ...This page intentionally left blank...
Страница 42: ...This page intentionally left blank...
Страница 47: ......
Страница 50: ......
Страница 56: ...This page intentionally left blank...
Страница 60: ...This page intentionally left blank...