Mechanical Installation
11
Ad Panel Mounting
Use the mounting methods outlined in this section for static ad panels. These methods are
also used for ADPC and ADTI displays.
Note:
Do not use lubrication on any mounting hardware or the warranty will be void!
Clamping Angles
Reference Drawings:
Ad Panel Mounting ..............................................................................................
DWG-52187
Mounting hardware includes mounting channels; rear clamping angles; 1/2-13 x 15"
threaded rods; and 1/2" square nuts, hex nuts, and lock washers. Refer to
DWG-52187
in
Appendix B
.
Note:
The threaded rods do not pass through the beams; they run along both sides.
1�
Position the ad panel at the front of the beams, and lift it to the desired height.
2�
Using a clamping angle as a template, drill two 9/16" holes in the upper rear flange of
the ad panel cabinet where the mounting channel support will be placed.
3�
Position a mounting channel inside the ad panel cabinet along the rear flange as
shown in
4�
Place 1/2" square nuts inside the mounting channel, and thread the rods through the
rear flange of the ad panel cabinet and the mounting channel.
5�
Slide clamping angles over the other ends of both threaded rods, and then loosely
install the washers and nuts.
6�
Make final adjustments to the ad panel position to ensure it is flush and level, and
firmly tighten all of the 1/2" hex nuts.
7�
Repeat
Steps 2–6
for every connection point to the beam. For example, if there are
two beams, there will be four connection points.
1/2" Hex Nut
1/2" Lock Washer
Clamping Angle
1/2" Square Nut
1/2-13 X 15" Threaded Rod
Beam
Ad Panel
Mounting
Channel
Figure 12:
Ad Panel Clamping Angle Mounting, Side View
Содержание FB-2700 Series
Страница 38: ...This page intentionally left blank...
Страница 42: ...This page intentionally left blank...
Страница 47: ......
Страница 50: ......
Страница 56: ...This page intentionally left blank...
Страница 60: ...This page intentionally left blank...