Electrical Installation
28
Top Section
Middle Section
Bottom Section
(Power & Signal
Terminated
in this Section)
(Coiled Interconnect Cables
Located in this Section)
A2
Driver
A5
Driver
Power Panel
J52
P52
J51
P51
J50
P50
Figure 32:
Power/Signal – TN-2650 & TN-2651
Four-Section Tennis Models
The primary driver and power panel will be located in the top section (Section A). Refer
to the component location drawings attached to the product specification sheets listed
in
Appendix A
for exact driver locations.
Open access panels as needed to locate the coiled bundles of interconnect cable,
then route and connect the cables as described below and shown in
1�
Route the interconnect cable labeled
P50
coming from the A3 driver in Section B up
into Section A and connect it to the mating
J50
jack coming from the power panel.
2�
Route one end of the interconnect cable labeled
P51
from Section B up into Section
A and connect it to the mating
J51
jack coming from the power panel.
3�
Route one end of the interconnect cable labeled
P52
from Section B up into Section
A and connect it to the mating
J52
jack coming from the power panel.
4�
Route the interconnect cable labeled
P51
coming from the A5 driver in Section C up
into Section B and connect it to the interconnect cable labeled
J51
.
5�
Route the interconnect cable labeled
P52
in Section C up into Section B and
connect it to the interconnect cable labeled
J52
.
6�
Route the interconnect cable labeled
P53
coming from the A7 driver in Section D up
into Section C and connect it to the interconnect cable labeled
J53
.