7. Use the (6) Phillips screws provided to retain
the display panel.
8. Set the new lens face down and use the lines etched in the back of the lens to line up the indicator light
panels. Use tape to position them before applying a light bead of silicone around the edge to secure them.
9. Place the lens on the instrument cluster in place of the original separator plate and re-assemble the
cluster.
10. The stock indicators can be used for everything but the high beam and turn signals. See main
instruction manual for remainder of installation.
A
new wire for the oil pressure sending unit must be used.
The stock oil pressure sender wire has a resistor inline and will cause the gauge to read incorrectly if used.
The stock water temp wire can be spliced into and used but the connector will need to be removed.