41
Groups enabled
* 41 * ? ? ? ? **
group 1 choice of group(s): 1 to 8*
25
in Armed Partial One
Groups enabled
* 42 * ? ? ? ? **
group 2 choice of group(s): 1 to 8*
25
in Armed Partial Two
Groups enabled in
* 43 * ? ? ? ? **
group 1 choice of group(s): 1 to 8*
25
Armed Presence mode
Programming
* 44 * C * A **
disabled C: common group n° (from 1 to 8)*
25
of common group A: choice of association group(s) (from 1 to 8)*
Arming blocked
* 45 * ? **
blocked blocking condition
19
if supervision 0: blocking disabled
command not 1: blocking if faults
received (20 min) 2: blocking if self-monitoring (mechanical
and exits checked
tamper fault and fault on transmission
at the end of exit
media or exit(s) open)
time delay 3: blocking if supervision not received (20 min)
4: blocking if supervision not received (20 min)
and exits checked at end of exit time delay
Relay 1 output activation depending on the type type of relay type of activation:
28
of relay triggering triggering: bistable A = event appearance
• bistable: D = event disappearance
* 46* 0 * A * D **
A and D = 0: manual (keypad or radio command)
• impulse: 0: manual 1: single intrusion
* 46 * 1 * A
2: confirmed intrusion
• timer: 3: confirmed intrusion (+ tamper
* 46 * 2 * A * T **
and alert command)
4: deterrence
5: prealarm
6: fire
7: technical
8: system disarmed
9: system armed
10: PSTN network cut
11: GSM network cut
12: ADSL network cut
13: main dialler unavailable
14: all
T = relay activation duration:
Impulse: 0.5 s
Timer: from 1 s to 180 s
Relay 2 output activation depending on the type type of relay type of activation:
28
of relay triggering triggering: bistable A = event appearance
• bistable: D = event disappearance
* 47* 0 * A * D **
A and D = 0: manual (keypad or radio command)
• impulse: 0: manual 1: single intrusion
* 47 * 1 * A
2: confirmed intrusion
• timer: 3: confirmed intrusion (+ tamper
* 47 * 2 * A * T **
and alert command)
4: deterrence
5: prealarm
6: fire
7: technical
8: system disarmed
9: system armed
10: PSTN network cut
11: GSM network cut
12: ADSL network cut
13: main dialler unavailable
14: all
T = relay activation duration:
Impulse: 0.5 s
Timer: from 1 s to 180 s
Relay tamper loop
* 48 * ? **
disabled 0: disabled
-
activation 1: enabled
Hardwired input
* 57 * T **
disabled T = input type:
27
programming 0: disabled
1: exit
2: intrusion
3: deterrence
4: prealarm
5: fire
6: technical
8: alert
9: silent alarm
10: chime
Parameter Parameter-setting Factory Possible values Page
description sequence parameters
Control panel parameters (cont.)