Control panels manage:
• intrusion protection,
• technical protection,
• fire protection,
• tamper alerts,
• system device faults.
Protection against intrusion is ensured by intrusion detectors that have first been programmed for recognition by the control
panel.
The triggering of alarms depends on the system status and type of detectors activated.
The
protection of individuals
(e.g.
silent alarm
), and
technical
and f
ire
protection devices operate
24 hours a day
.
The control panel is protected against opening and removal.
If an alarm is triggered, the dialler and sirens are activated.
The control panel, which can control 2 to 8 separate protection groups (according to the type of control panel), is fitted with:
• an integral control keypad,
• a siren,
• a speech synthesis loudspeaker.
The different types of control panel are:
1. Introduction
Control panel reference
Number of groups
Number of detectors
Number of user codes
SH320AU
2
20
SH340AU
4
40
32
SH380AU
8
80
IMPORTANT
• Some functions are only available with control panel versions 2.0.0 or later (enter
on the control
panel keypad to check the version).
• Operational differences in relation to former ranges are described in the compatibility booklet available in the Daitem Installers
section at www.daitem.co.uk.
Depending on its reference, the transmission module uses
different media (see table opposite, unused media must be
declared).
When installing the product, it should be assumed that the
transmission module can have three transmission media:
PSTN, GSM/GPRS and ADSL.
The installation of an optional transmission module
(not originally installed in the control panel) confers two additional
functions on the control panel.
Via its different communication networks, the transmission module makes the following possible:
1.
remote alerts in case of intrusion or events occurring on the protected site.
• The control panel-dialler warns individual correspondents and/or a remote monitoring centre in the event of:
- intrusion,
- technical alarms,
- fire alarms,
- tamper alerts,
- faults in one of the system devices.
• In the event of intrusion, the control panel-dialler makes the following remote operations possible:
- listen-in and speak-out/talk-back,
- visual alarm confirmation via the transmission of images or films from the image transmission motion detectors
and/or compatible IP cameras installed on the protected site.
2.
remote access to the protected site:
• alarm system operation,
• parameter-setting,
• checking.
The transmission modules are:
Module
reference
Transmission media
SH501AX
PSTN
-
Ethernet
(ADSL)
SH502AX
-
GSM/GPRS
SH503AX
PSTN
GSM/GPRS
SH504AX
-
-
GSM
/
GPR
S
ETHE
RNE
T
(ADS
L)
fi
Only concerns transmission modules using the media indicated
(
example here
: GSM/GPRS and Ethernet (ADSL)).