36
The control panel monitors its own battery.
When a power fault occurs, the control panel issues the voice message
“fault, power supply”
following a command.
To change the battery:
12.
Reconnect the telephone connector to
the wall socket (1).
13.
Put the control panel in user mode:
10.4 Changing the battery
IMPORTANT: the date and time must
be reprogrammed after changing the
battery.
• The lithium battery pack must be replaced with the same type of pack with the same technical characteristics,
i.e. 2 x (3.6 V - 13 Ah).
• We advise you to use the DAITEM BatLi22 battery available in the catalogue in order to guarantee individual
safety and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
INSTALLATIO
N
MODE
Li
(1) If transmission module installed.
Unlocking key
IMPORTANT
• If the activated product (except for the remote control unit) has a power fault (lithium power pack flat), the control panel
indications are followed by the message
“fault, power supply”
.
• Before changing the battery, disconnect the telephone connector from the wall socket (1).
1.
Disarm the system:
4.
Disconnect the telephone connector from the wall socket (1).
5.
Loosen the locking screw on the bottom right-hand side of the
control panel.
6.
Introduce a screwdriver into the bottom
right-hand side of the base and push
to open the control panel.
7.
Press on the unlocking key and slide the flat
lithium power pack downwards.
8.
Wait for 2 min,
9.
Position the new lithium power pack on the
guide rails and slide it upwards until it locks
into position.
3.
Put the control panel in installation mode
then,
2.
Remove the control panel cover.
Side view
Control panel locking
Control panel opening
10. A.
Close the control panel.
B.
Put the cover back on.
11.
Lock the control
panel using the
screw.
A
B
master code (Factory: 0000)
installer code (Factory: 1111)