29
Inhibiting and reactivating a product
• To inhibit a product, enter:
type of
product
product
n°
Deleting parameters
To delete all parameters, enter:
Overall deletion
To delete all recognition programming and return to the factory configuration, enter:
type of
product
product
n°
• To reactivate a product, enter:
Before fixing the products in place, position them close to their final location and check the radio links with the control panel.
If the link with the control panel is satisfactory, the control panel issues a voice message identifying the product activated.
8.2.1 Choosing the radio link test
In installation mode, the control panel is factory-configured to respond to the correct receipt of a radio message on one of
the two frequency bands.
To modify this configuration, refer to the summary of parameters at the end of this manual.
8.2.2 Testing the remote control units
Press the
“Off”
button on the remote control units and the control panel
will issue the voice message:
“bip, off, remote control unit X”
.
8.2 Testing the radio links
“bip, off, remote
control unit X”
)
)
)
)
)
8.1 Choosing the best place to install the control panel
8. Installing a control panel without a transmission module
IMPORTANT: make sure there is a distance of at least 2 metres between each product, except between two detectors.
Position the control panel without fixing it:
• inside, in a protected area,
• on a flat and rigid surface close to an electrical socket if you are using a mains power supply,
• far away from any sources of disturbance (electricity meter or switchboard, computer equipment, a plant room, etc.),
• preferably in the centre of the installation,
• with enough clearance to facilitate cover opening and cable threading.
The control panel must never be fixed directly on to a metal surface.
For the control panel to work properly:
• never leave extra cable inside the box.
• do not wind cable around the box.
For the following types of installation:
• control panel
without transmission module:
follow the complete installation procedure as described in this manual.
•
control panel-dialler:
follow the complete installation procedure as described in the installation manual common to the
control panel-dialler and stand-alone dialler:
“Setting the parameters and implementing transmission with the
transmission module”
manual.
7. Installing and implementing control panel-dialler transmission
Type of product
Number
Detector
2
Remote control unit
3
Siren
4
Dialler
5
Radio repeater relay or receiver
7