To ensure long-lasting radio link reliability, once the products have been installed,
each radio link must be checked
carefully.
To do this, repeat the operations described below for all installed products.
This check must be performed in installation mode.
8.5.1 Checking remote control units
Press the
“Off”
button on the remote control units and the control panel
will issue the voice message:
“bip, off, remote control unit X”
.
8.5.2 Checking keypads
Press the “
Off”
button on the keypads and the control panel will issue
the voice message:
“bip, off, remote control unit X”
.
8.5.3 Checking door/window or multicontact detectors
• Press the
“test”
button on the detectors (> 5 s) and the control panel
issues the voice message:
“bip, test, detector X, group Y,
(immediate, time-delayed or combined)”
.
• Open the protected exits and the control panel will issue the voice
message:
“bip, intrusion, detector X”
.
8.5.4 Checking motion detectors
• Press the “test” buttonon the motion detectors (> 5 s) and the control panel
issues the voice message:
“bip, test, detector X, group Y,
(immediate, time-delayed or combined)”
.
• Move around in the area protected by the motion detectors and the
control panel issues the voice message:
“bip, intrusion, detector X”
.
8.5.5 Checking sirens, radio repeater relays and receivers automatically
This test checks the two-way radio link between the control panel, sirens, r
adio repeater relays and receivers. The control panel queries and activates the sirens,
radio repeater relays and receivers 3 times. Enter:
Example with siren: • the control panel issues the voice message:
“bip, test, siren X”
,
• the siren issues a continuous beep and its strobe flashes for 3 s.
IMPORTANT: if the sirens, radio repeater relays or receivers have a power supply fault (lithium
power pack flat), the siren, radio repeater relay and receiver indications are followed by an
audible signal specifying this fault.
8.5 Checking products and radio links
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
“bip, off, remote
control unit X”
“bip, test, detector X,
group Y, (immediate, time-
delayed or combined)”
“bip, test, detector X,
group Y, (immediate, time-
delayed or combined)”
(
(
(
(
(
(
(
(
(
(
“bip, test, siren X”
)
)
)
)
)
“bip, off, remote
control unit X”
“beeep”
(
(
(
(
(
(
(
(
(
(
or
6. A.
Close the control panel.
B.
Put the cover back on.
7.
Lock the control panel
using the screw in the
bag of accessories.
A
B
Side view
Control panel locking