B. Programming the relay outputs
The control panel has 2 relay outputs.
Each relay can be programmed according to the type of alarm concerned.
To perform this programming, enter:
• Programming a bistable relay:
Appearance or disappearance event
• 0: manual (upon keypad or radio command)
• 1: single intrusion
• 2: confirmed intrusion
• 3: confirmed intrusion
(+ tamper and alert command)
• 4: deterrence
• 5: prealarm
• 6: fire
• 7: technical
• 8: system disarmed
• 9: system armed
• 10: PSTN network cut
• 11: GSM network cut
• 12: ADSL network cut
• 13: main dialler unavailable
• 14: all
6: relay 1
7: relay 2
appearance
event
(see table
opposite)
disappearance
event (see table
opposite)
• Programming a timer relay:
6: relay 1
7: relay 2
from 1 to 120 s
appearance
event (see table
opposite)
• Programming an impulse relay (0.5 s relay activation):
6: relay 1
7: relay 2
appearance event
(see table opposite)
Blue light indication
To activate or deactivate the control panel blue light, enter:
Factory: enabled
0: disabled
1: enabled
Setting the parameters of the automatic disarming/arming function
If activated, this function makes it possible to automatically send arm and disarm commands to the alarm control panel.
Using TwinLoad
®
software, programming can apply to a 7-day period. Each programming point must be associated with a
disarm or arm order.
To perform this programming, use the control panel keypad and proceed as follows:
Factory: disabled
0: disabled
1: enabled
Setting the parameters of the chime function
When the system is disarmed, each time there is movement in front of the motion detector or each time a door/window
detector is activated, the control panel issues a ding dong.
To perform this programming, enter:
Factory: disabled
detector n°
0: disabled
1: enabled
If the hardwired input is configured for an exit, intrusion, deterrence or prealarm, it is factory allocated to group 1 set for
immediate triggering.
To modify this allocation, enter:
Factory: hardwired input allocated to group 1 set for immediate triggering
...
groups
1 to 8
0: immediate
1: time-delayed
2: combined