GB
113
4.1 Inhibiting the detector
To prevent untimely triggering due to activities likely to generate smoke or dust (sweeping a dusty
room, sweeping a chimney, etc.), the detector can be deactivated for roughly 15 min.
To do this, press one time on the test button. The detector beep, the red LED flash every 2 s.
After 15 min or after the manual test, the detector automatically becomes operational once more.
4. Using the detector
IMPORTANT
• During these 15 minutes, the detector will not be able to recognise smoke or heat or generate an
alarm.
• To exit inhibition mode more quickly, press the detector test button. The detector beep, the red
LED stop flashing.
Inhibited detector
Other interconnected detectors
1 flash every 2 seconds
-
4.2 Stopping the alarm in the event of non-dangerous detection
To stop the alarm if it has detected harmless smoke:
• press the test button,
or
• press one of the keys on an infrared remote control (remote control of a TV, DVD player, hi-fi system)
and point the remote control towards the sounding detector.
The detector will switch to inhibited mode (see chapter 4.1) for 15 minutes.
Please note that the alarm can be stopped 20 s after the detector triggers the system.
If the detector is associated with a Daitem alarm system (see chapter 2.5), press the
“Off”
key on a
remote control device to stop the control panel and sirens.