SK-20NZ SMOKE ALARM INSTALLATION INSTRUCTIONS 

Thank you for buying a Sentech photoelectric smoke alarm. Please read all 

instructions before installing the smoke alarm, so it will protect your home in the 

best possible way. 
•  If you are installing the smoke alarm for some other person, leave these 

instructions or a copy of them with him/her. 

•  The Sentech photoelectric smoke alarm is also suitable for use in camper 

vans, caravans, and boats. 

1.  POSITIONING THE SMOKE ALARM 

• Place at least one smoke alarm per room, with a maximum area of 60 m'. 
• Place a smoke alarm in each corridor and bedroom. 
• The smoke alarm should be placed on the ceiling and ideally close to the 

middle of the room. 

• Place a smoke alarm at the top of each staircase. 

Caution: 

Incorrect installation will 

decrease operational effectiveness. 

o/ 

Place 

the smoke alarm on the ceiling and position it 

at least 50cm away from the wall and corner. 

Bedroom 

Hall 

Bedroom 

J ... _, _______ 

! .....[

��  Heat Alarm 

Kitchen 

Preferred 

Cellar 

• 

Compulsory location 

• 

Recommended location 

AVOID THESE POSITIONS: 
Near a wall or corner: 

Place the smoke alarm at a distance of at least 50cm from 

a wall or corner. 

Moist places: 

Avoid installing smoke alarms near moist or occasionally moist 

places such as a shower or kitchen, where steam may cause a false alarm. 

Ventilation ducts: 

Avoid installing a smoke alarm immediately next to a ventilation 

duct. The draft may prevent smoke from reaching the smoke alarm.  Smoke 

alarms can't be installed in a location where the air velocity is more than 300ft/min 

(1.5 m/sec). 

Dead-air spaces: 

Avoid installing a smoke alarm in the angle of a pitched roof. 

Install it at a distance of least 10cm from the ridge. 

Fluorescent lamps: 

Avoid installing a smoke alarm immediately next to 

fluorescent lamps, such as halogen lights. 

Radiation heating source: 

Avoid installing a smoke alarm radiant heating source. 

Radiant heating in the ceiling can create a hot air barrier layer along the ceiling 

surface which can seriously restrict the movement of smoke and heat towards a 

smoke alarm. 

2:  OPERATION AND TESTING 
Normal mode: 

The red light flashes once every 344 seconds (roughly 6 minutes) 

in normal mode. 

Alarm mode: 

When the smoke alarm detects smoke, it goes into alarm mode in 

which the smoke alarm beeps continually and the red light flashes. 

Test mode: 

Most of the alarm top/face is the test button. Press the test button 

until you hear the alarm sound and see the light flash. Release the button and the 

smoke alarm will go into silence mode (9 minutes). 

Silence mode: 

During alarm mode, press the test button for 1 second to reset the 

smoke alarm.  The beep is silenced when the test button is released - the alarm 

then enters in to a 9 minute silence mode.  In silence mode, the red light flashes 

once every 10 seconds to indicate that the mode is active. 
The silence mode will be cancelled if any of the following conditions exist: 

• High smoke level. • Test button is activated again. 

Error mode: 

The smoke alarm sends out a 'beep' three times every 43 seconds. 

Remove the smoke alarm from the mounting plate and clean up the surface dust, 

then re-install. If the smoke alarm remains in error mode, contact the distributors 

as listed. 

Low battery: 

When the battery is used up, the smoke alarm beeps at intervals of 

43 seconds.  You can silence the beep by pressing the test button for 3 seconds 

- during the 3 seconds the red light stays on and the beep sounds. After the 3 

seconds release the test button, and the 'beep' prompt is silenced for 8 hours. 

Pressing the test button for 3 seconds then releasing will also activate the smoke 

alarm in to a 9- minute silence mode.  At the end of the 8 hours, the audible 

indication will resume if the low battery condition still exists. 

Local Alarm Memory: 

If the smoke alarm goes into alarm mode, it will enter the 

24 hours local alarm memory state after exiting alarm mode. 

In local alarm memory state, the green light flashes three times at 1.3 second 

intervals - this pattern will repeat every 43 seconds, and will stop after 24 hours, 

returning to normal mode.  You will still be able to identify a unit with an alarm 

memory by pressing the test button. When you press test button, the 'beep' 

sound will be once every 0.25 seconds - release the test button to revert from the 

local alarm memory state. The initial 24 hours visual indication is not displayed if 

the smoke alarm is in the low battery condition. 

End of life indicator: 

After 10 years of operation, an audible warning signal 

occurs to indicate that the smoke alarm should be replaced. This indicator will 

be similar to the error mode warning that the smoke alarm sends out 'beep' three 

times every 43 seconds. 

3.  MAINTENANCE 

Battery life: 

The smoke alarm contains a 3V lithium battery (CR123A). The lifetime 

is 10 years. When the battery is used up, the smoke alarm beeps at intervals of 43 

seconds for at least 30 days.  If the battery is used up, replace the smoke alarm as 

soon as possible. 

WARNING: 

Lithium batteries can explode or cause burning if installed incorrectly. 

Do not attempt to replace the battery. 

Clean the smoke alarm at least once a year. Separate the smoke alarm carefully 

from the installation plate by turning it counter-clockwise. 
Test the smoke alarm after cleaning it. Do not paint or modify the smoke alarm. 

Waste handing: 

The smoke alarm should be disposed in accordance with normal 

waste handing for electronics. 

4.  TECHNICAL INFORMATION 

Operating principle: Photoelectric 

Alarm current: < 200mA 

Dimensions: 42.5 x 050.8mm 

Maximum humidity: 93% 

Quiescent current: < 3uA 

Weight: 54 g 

5. MANUFACTURER'S GUARANTEE 

Warranty: 5 years 

Sound volume: "' 85 dB 

at a distance of 3 meters 

Holding temperature of 

3M attachment tape -35

°

C~ 93

°

Voltage: 3V (built-in lithium battery) 

Operating temperature: 0

°

C- 45

°

Conform to the standard:  EN 14604 

The manufacturer provides a 5 year guarantee, starting from the purchase date 

of the product.  If the smoke alarm becomes defective during the guarantee 

period, the smoke alarm will be replaced with a new one providing the defective 

one is returned to the distributor. The guarantee covers manufacturing or material 

defects in the product, if the smoke alarm has been used according to the user 

instructions and the guarantee period has not expired.  The guarantee period for 

a smoke alarm that has been replaced with a new one is the same as that of the 

original smoke alarm. 

The guarantee is not valid if: 

1)  the product is used, maintained, or tested contrary to the user instructions, 
2)  the defect has been caused by a negligent act by other than the manufacturer, 
3)  if the product has been modified or treated with force, 
4)  if it the guarantee receipt is missing. 
The guarantee does not cover costs due to installation or battery replacement. 

The manufacturer's responsibility does not in any case exceed the price of a new 

smoke alarm. The manufacturer is not responsible for any damage or loss that has 

been caused by a non-working smoke alarm or negligence by the manufacturer. 

This guarantee does not affect rights enacted by law. 