Domestic hot water tank for Daikin Altherma Monobloc (R32)
11
Digital Controller for the On
-
board Pump
11.1
Digital Controller Front Panel Commands
11.2
Digital Controller Wiring Connections
NOTICE
•
The Dixell stat is set at 37
o
C from the factory. This setpoint can be
changed by using the Dixell control panel. We recommend the
setpoint to be 37
o
C however it could be changed based on your
requirements .e.g. if using low temperature heat emitters.
•
If there is no possibility for water circulation on the secondary
side, an automatic bypass valve should be fitted. Water circula-
tion could be via a towel rail, a by
-
pass valve or a radiator with-
out a TRV.
•
Do NOT use Dixell control panel for DHW setpoint. This control
panel should only be used to set the water temperature used to
run the on board pump for space heating.