2
|
Components
Service manual
79
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01C – 2020.07
Is the problem solved?
Action
No
Return to
continue with the next procedure.
To remove the main PCB
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
92].
1
Disconnect all connectors from the main PCB.
a
a
b
b
a
a
Screw
b
PCB support
2
Remove the screws from the main PCB.
3
Carefully pull the main PCB from the PCB supports
4
Remove the main PCB from the unit.
5
78].
To install the main PCB
1
Apply grease to the PCB contact surface of the heat sink. Distribute the grease
as evenly as possible.
CAUTION
ALWAYS apply new grease on the PCB heat sink. NOT doing so may cause the PCB to
fail due to insufficient cooling.
2
Install the main PCB in the correct location on the PCB supports.