2
|
Components
Service manual
85
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01C – 2020.07
4
To install the propeller fan blade assembly, see
To remove the DC fan motor assembly
1
Remove the propeller fan blade assembly from the DC fan motor assembly,
see
2
Disconnect the DC fan motor connector from the main PCB.
3
Unlock the ferrite bead.
4
Cut the tie strap.
5
Detach the DC fan motor harness from the switch box.
6
Slightly bend the harness retainers to detach the DC fan motor harness.
7
Remove the 4 screws that fix the DC fan motor assembly.
8
Remove the DC fan motor assembly from the unit.
9
To install the DC fan motor assembly, see
84].
To install the DC fan motor assembly
1
Install the DC fan motor assembly in the correct location.
2
Fix the DC fan motor assembly to the unit by tightening the screws.
3
Route the DC fan motor harness through the harness retainers and bend the
harness retainers to attach the DC fan motor harness.
4
Attach the DC fan motor harness to the switch box.
5
Install a new tie strap to fix the DC fan motor harness to the switch box.
6
Connect the DC fan motor connector to the connector on the main PCB.
7
Lock the ferrite bead.
8
Install the propeller fan blade assembly, see
To install the propeller fan blade assembly
1
Install the propeller fan blade assembly on the DC fan motor assembly.
CAUTION
Do NOT install a damaged propeller fan blade assembly.
2
Install and tighten the nut to fix the propeller fan blade assembly.
a
b