115
RXG50K3V1B
5.13 Capacitor Voltage Check
Check No.21
RXG50K2V1B only
Before this check, be sure to check the main circuit for short circuit.
With the circuit breaker still on, measure the voltage according to the drawing of the model in
question. Be careful never to touch any live parts.
Tester
–
~
~
+
1
2
3
4
– +
(R14700)
Multimeter
(DC voltage range)
(R18183)