SiBE06-514A
Main Functions
Function and Control
29
1.11
Other Functions
1.11.1
Hot Start Function
Heat Pump Only
In order to prevent the cold air blast that normally comes when heating is started, the
temperature of the heat exchanger of the indoor unit is detected, and either the air flow is
stopped or is made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat gets turned ON.
1.11.2
Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.11.3
ON/OFF Button on Indoor Unit
An ON/OFF switch is provided on the front panel of the unit. Use this switch when the remote
controller is missing or if its battery has run out.
Every press of the switch changes from Operation to Stop or from Stop to Operation
Push this button once to start operation. Push once again to stop it.
This button is useful when the remote controller is missing.
The operation mode refers to the following table.
In the case of multi system operation, there are times when the unit does not activate with
this button.
1.11.4
Photocatalytic Deodorizing Filter
Photocatalytic Deodorizing Filter demonstrates powerful oxidation characteristics when
subjected to harmless ultraviolet light. Photocatalytic deodorizing power is recovered simply by
exposing the filter to the sun for 6 hours once every 6 months.
1.11.5
Air-Purifying Filter
A double structure made up of a bacteriostatic filter and an Air-Purifying Filter traps dust,
mildew, mites, tobacco smoke, and allergy-causing pollen. Replace the Air-Purifying Filter once
every 3 months.
1.11.6
Mold Proof Air Filter
The filter net is treated with mold resisting agent TBZ (harmless, colorless, and odorless). Due
to this treatment, the amount of mold growth is much smaller than that of normal filters.
Mode
Temperature setting
Air flow rate
Cooling Only
COOL
22ºC
AUTO
Heat Pump
AUTO
25ºC
AUTO
Содержание FVKS25BVMB
Страница 10: ...SiBE06 514A List of Functions 1 Part 1 List of Functions 1 List of Functions 2 ...
Страница 13: ...List of Functions SiBE06 514A 4 List of Functions ...
Страница 14: ...SiBE06 514A Specifications 5 Part 2 Specifications 1 Specifications 6 1 1 Cooling Only 6 1 2 Heat Pump 8 ...
Страница 19: ...Specifications SiBE06 514A 10 Specifications ...
Страница 25: ...Printed Circuit Board Connector Wiring Diagram SiBE06 514A 16 Printed Circuit Board Connector Wiring Diagram ...
Страница 57: ...Control Specification SiBE06 514A 48 Function and Control ...
Страница 85: ...Instruction SiBE06 514A 76 System Configuration ...
Страница 133: ...Check SiBE06 514A 124 Service Diagnosis ...
Страница 154: ...SiBE06 514A Outdoor Unit Removal Procedure 145 When reassembling make sure to fit the hook Step Procedure Points ...
Страница 168: ...SiBE06 514A Others 159 Part 8 Others 1 Others 160 1 1 Test Run from the Remote Controller 160 1 2 Jumper Settings 161 ...
Страница 171: ...Others SiBE06 514A 162 Others ...
Страница 177: ...Wiring Diagrams SiBE06 514A 168 Appendix ...
Страница 181: ...SiBE06 514A iv Index ...