When 2 Units are Installed in 1 Room
When 2 indoor units are installed in 1 room, 1 of the 2 pairs of indoor unit and wireless remote
controller can be set for different addresses.
Both the indoor unit PCB and the wireless remote controller need alteration.
Indoor Unit PCB
Cut the address setting jumper JA on the control PCB.
Wireless Remote
Controller
Cut the address setting jumper.
09/12 class
15/18/24 class
JA
(R12008)
JA
EXIST
CUT
ADDRESS
1
2
Address
JA
(R14261)
JA
EXIST
CUT
Address
1
2
(R13525)
ADDRESS
Jumper
EXIST
CUT
1
2