Outdoor Unit: 09/12 Class
SiUS041111
182
Removal Procedure
10
Feature of the control
PCB
[S10] [HN3] [HL3]: filter PCB
[S20]: electronic expansion valve
coil
[S40]: overload protector
[S70]: fan motor
[S80]: four-way valve coil
[S90]: thermistors
5. Remove the filter PCB.
1
Remove the screw of
the ground.
2
Cut the clamp.
Step
Procedure
Points
[S70]
[S10]
[S90]
[S40]
[S20]
[S80]
[HL3]
[HN3]
(R11784)
Ground
(R11785)
Filter
PCB
(R11786)