Ceiling Mounted Cassette Type
SiEN18-622
274
System Configuration
•
Keep doors and windows closed. If the doors and windows
remain open, room air will flow out and cause to decrease
the effect of cooling and heating.
•
Do not place other heaters directly below the indoor unit.
They may deform due to the heat.
•
Never place objects near the air inlet and the air outlet of
the unit. It may cause deterioration in the effect or stop in
the operation.
•
Turn off the main power supply switch when it is not used
for long periods of time. When the main power switch is
turned on, some watts of electricity is being used even if
the system is not operating. Turn off the main power
supply switch for saving energy. When reoperating, turn on
the main power suply switch 6 hours before operation for
smooth running (Refer to MAINTENANCE).
•
When the display shows “
” (TIME TO CLEAN AIR
FILTER), ask a qualified service person to clean the filters
(Refer to MAINTENANCE).
Only a qualified service person is allowed to perform
maintenance
IMPORTANT!
•
Before obtaining access to terminal devices, all power
supply circuits must me interrupted
•
To clean the air conditioner, be sure to stop operation, and
turn the power switch off. Otherwise, an electric shock and
injury may result.
•
Do not wash the air conditioner with water.
Doing so may result in an electric shock.
•
Be careful with a scaffold or staging.
Caution must be exercised because of work at a high
place.
How to clean the air filter
Clean the air filter when the display shows “
”
(TIME TO CLEAN AIR FILTER).
It will display that it will operate for a set amount of time.
Increase the frequency of cleaning if the unit is installed in a
room where the air is extremely contaminated.
If the dirt becomes impossible to clean, change the air filter
(For changing air filter, please contact your dealer.)
1. Open the suction grille
Push it downward slowly while pressing horizontally the
buttons provided on two spots.
(Follow the same procedure for closing).
Fig. 1
2. Remove the air filter
Pull the hook of the air filter out diagonally downward, and
remove the filter.
Fig. 2
3. Clean the air filter
Use a vacuum cleaner A) or wash the air filter with water B).
A) Using a vacuum cleaner
B) Washing with water
When the air filter is very
dirty, use soft brush and
neutral detergent.
Remove water and dry in the shade.
NOTE
•
Do not wash the air conditioner with hot water of more than
50°C, as doing so may result in discoloration and/or
deformation.
•
Do not expose it to fire, as doing so may result in buring.
8. Maintenance
(For service personnel)
Содержание FTKS50BVMB
Страница 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Страница 30: ...SiEN18 622 Specifications 17 Part 2 Specifications 1 Specifications 18 1 1 Cooling Only 18 1 2 Heat Pump 34 ...
Страница 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Страница 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Страница 204: ...Instruction SiEN18 622 192 System Configuration FTK X S 50 60 71 F Indoor Unit 1 2 4 3 10 11 9 7 8 15 12 13 14 16 6 5 ...
Страница 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Страница 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Страница 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...