4.5.5 Fan Speed Changeover When Thermostat is OFF
By setting to “Set Fan Speed,” you can switch the fan speed to the set fan speed when the
heating thermostat is OFF.
∗
Since there is concern about draft if using “fan speed up when thermostat is OFF,” you should
take the setup location into consideration.
Setting Table
4.5.6 Wireless Setting (Address and MAIN/SUB Setting)
Explanation
If several infrared remote control units are used together in the same room (including the case
where both group control and individual remote control control are used together), be sure to set
the addresses for the receiver and infrared remote control. (For group control, see the attached
installation manual for the indoor unit.) If using together with a wired remote control, you have to
change the main/sub setting or the receiver.
Receiver Setting
Set the wireless address switch (SS2) on the transmitter board according to the table below.
When using both a wired and a infrared remote control for 1 indoor unit, the wired controller
should be set to MAIN. Therefore, set the MAIN/SUB switch (SS1) of the transmitter board to
SUB.
After completing setting, seal off the opening of the address switch and the MAIN/SUB switch
with the attached sealing pad.
Mode No.
First Code No.
Second Code No.
Setting
12(22)
3
01
LL Fan Speed
02
Set Fan Speed
Unit No.
No.1
No.2
No.3
Wireless Address
Switch (SS2)
MAIN
SUB
MAIN/SUB Switch
(SS1)
123 MS
SS2 SS1
(S1940)
Содержание FTKS50BVMB
Страница 1: ...SiEN18 622 E Series Service Manual Applied Models zSuper Multi Plus Cooling Only Heat Pump ...
Страница 30: ...SiEN18 622 Specifications 17 Part 2 Specifications 1 Specifications 18 1 1 Cooling Only 18 1 2 Heat Pump 34 ...
Страница 105: ...Refrigerant Flow for Each Operation Mode SiEN18 622 92 Refrigerant Circuit ...
Страница 157: ...Indoor Unit SkyAir Models SiEN18 622 144 Function ...
Страница 204: ...Instruction SiEN18 622 192 System Configuration FTK X S 50 60 71 F Indoor Unit 1 2 4 3 10 11 9 7 8 15 12 13 14 16 6 5 ...
Страница 312: ...SiEN18 622 Ceiling Mounted Cassette Type System Configuration 300 ...
Страница 424: ...Method of Replacing The Inverter s Power Transistors Modules SiEN18 622 412 Troubleshooting ...
Страница 446: ...Wiring Diagrams SiEN18 622 434 Appendix ...
Страница 452: ...SiEN18 622 vi Index ...