SiENBE12-713
Instruction
System Configuration
107
Installation site
"
To install the air conditioner in the following types of environments, consult the dealer.
•
Places with an oily ambient or where steam or soot occurs.
•
Salty environment such as coastal areas.
•
Places where sulfide gas occurs such as hot springs.
•
Places where snow may block the outdoor unit.
The drain from the outdoor unit must be discharged to a place of good drainage.
Consider nuisance to your neighbours from noises
"
For installation, choose a place as described below.
•
A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration.
•
A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.
Electrical work
•
For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation
•
Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is
necessary for moving or remodeling
•
Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not
remove the fan guard.
•
Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In
certain conditions, moisture in the air may condense and drip.
•
After a long use, check the unit stand and fittings for damage.
•
Do not touch the air inlet and aluminum fins of outdoor unit. It may cause injury.
•
The appliance is not intended for use by young children or infirm persons without supervision.
•
Young children shuld be supervised to ensure that they do not play with the appliance.
•
To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used
together with the air conditioner.
•
Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply
cord.
•
Do not connect the air conditioner to a power supply different from the one as specified. It may
cause trouble or fire.
•
Depending on the environment, an earth leakage breaker must be installed. Lack of an earth
leakage breaker may result in electric shocks.
•
Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the
building, furniture etc.
•
Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris
accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can
cause malfunctions, smoke or fire when making contact with electrical parts.
•
Do not operate the air conditioner with wet hands.
•
Do not wash the indoor unit with excessive water, only use a slightly wet cloth.
•
Do not place things such as vessels containing water or anything else on top of the unit.
Water may penetrate into the unit and degrade electrical insulations, resulting in an
electric shock.
Содержание FTKS20D3VMW
Страница 11: ...Introduction SiENBE12 713 x...
Страница 47: ...Specifications SiENBE12 713 36 Specifications...
Страница 113: ...Control Specification SiENBE12 713 102 Function and Control...
Страница 122: ...SiENBE12 713 Instruction System Configuration 111 Names of Parts FTK X S 20 25 35 C Indoor Unit...
Страница 235: ...Instruction SiENBE12 713 224 System Configuration...
Страница 297: ...Check SiENBE12 713 286 Service Diagnosis...
Страница 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...
Страница 330: ...SiENBE12 713 Others 319 Part 8 Others 1 Others 320 1 1 Test Run from the Remote Control 320 1 2 Jumper Settings 321...