Control Specification
SiUS091601EA
81
Part 4 Functions and Control
5.3.3 Four Way Valve Operation Compensation
Outline
At the beginning of operation as the four way valve is switched, the pressure difference to activate
the four way valve is acquired when the output frequency is higher than a certain fixed frequency,
for a certain fixed time.
Details
Starting Conditions
1. When the compressor starts and the four way valve switches from OFF to ON
2. When the four way valve switches from ON to OFF during operation
3. When the compressor starts after resetting
4. When the compressor starts after the fault of four way valve switching
The lower limit of frequency keeps
A
Hz for
B
seconds for any of the conditions above.
When the outdoor temperature is above
C
in heating, the frequency decreases depending on the
outdoor temperature.
5.3.4 3-Minute Standby
Turning on the compressor is prohibited for 3 minutes after turning off.
The function is not used when defrosting.
5.3.5 Compressor Protection Function
When turning the compressor from OFF to ON, the upper limit of frequency is set as follows.
The function is not used when defrosting.
: Values refer to 15/18/24 class only, when outside temperature is lower than –15°C (5°F).
09 class
12 class
15 class
18/24 class
Cooling Heating Cooling Heating Cooling Heating Cooling Heating
A
(Hz)
40
54
24
34
48
46
48
B
(seconds)
60
60
70
60
C
(°C)
10
10
15
15
(°F)
50
50
59
59
09 class
12 class
15 class
15 class
18/24 class
A
(Hz)
40
24
52
35
55/48
B
(Hz)
54
34
68
52
65
C
(Hz)
72
44
80
62
80
D
(Hz)
90
56
98
80
90
E
(Hz)
100
78
—
100
100
F
(seconds)
180
180
300
1300
240
G
(seconds)
420
420
200
250
200
H
(seconds)
180
180
460
300
200
J
(seconds)
120
120
200
200
120
K
(seconds)
400
180
—
120
120
(sec.)
Time
(R23251)
(Hz)
Frequency
C
D
E
B
F
G
H
J
K
A
Содержание FDMQ12RVJU
Страница 14: ...SiUS091601EA 9 Part 1 General Information 1 Applicable Models 10 2 Functions 11 Part 1 General Information ...
Страница 18: ...SiUS091601EA 13 Part 2 Specifications 1 Specifications 14 Part 2 Specifications ...
Страница 132: ...Troubleshooting for FTX FVXS Series SiUS091601EA 127 Part 6 Service Diagnosis Reference Check No 01 Refer to P 181 ...
Страница 161: ...SiUS091601EA Troubleshooting for Outdoor Unit Part 6 Service Diagnosis 156 Reference Check No 14 Refer to P 185 ...
Страница 165: ...SiUS091601EA Troubleshooting for Outdoor Unit Part 6 Service Diagnosis 160 Reference Check No 18 Refer to P 190 ...
Страница 180: ...Troubleshooting for Outdoor Unit SiUS091601EA 175 Part 6 Service Diagnosis Reference Check No 19 Refer to P 191 ...
Страница 197: ...SiUS091601EA Check Part 6 Service Diagnosis 192 12 class 15 class Multimeter R23024 R25105 1 2 3 4 Multimeter ...
Страница 198: ...Check SiUS091601EA 193 Part 6 Service Diagnosis 18 24 class R24538 1 2 3 4 Multimeter ...
Страница 201: ...SiUS091601EA Check Part 6 Service Diagnosis 196 18 24 class R24539 DC DC W V U ...
Страница 228: ...Piping Diagrams SiUS091601EA 223 Part 8 Appendix 1 2 Outdoor Unit RXL09QMVJU RXL12QMVJU 9 3D100008 3D100009A ...
Страница 229: ...SiUS091601EA Piping Diagrams Part 8 Appendix 224 RXL15QMVJU RXL18UMVJU 3D100007 3D123368 ...
Страница 230: ...Piping Diagrams SiUS091601EA 225 Part 8 Appendix RXL24UMVJU 3D107985A ...