Operation
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
31
Setting the timer programme for the circulation pump
●
Place the rotary switch in the
"Configuration"
position.
An overview is displayed.
●
Select the
"DHW Configuration"
level with the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
An overview is displayed.
●
Select the parameter to be set with the rotary switch.
– [Circl-Pump DHW]: Setting as to whether the circulation
pump is actuated by the active hot water timer programme
[ON] or from a separate timer programme [OFF].
– [Circl-Pump Interval]: Setting the interval control for an
optional circulation pump.
●
Confirm the changes with a brief push of the rotary switch.
●
Setting parameters
●
Confirm the changes with a brief push of the rotary switch.
The circulation pump is actuated in accordance with the
settings made by the Controller RoCon HP.
Possible setting values for this rotary switch setting can be seen in chapter 6.2.4.
3.6.16 Remote control via Internet
Using an optional gateway (
EHS157056
), the Controller
RoCon HP can be connected to the internet. This means that the
Daikin Altherma EHS(X/H) can be controlled remotely via mobile
phone (using an App).
Intuitive operation is possible.