
3
x
Operation
Daikin RoCon HP
Daikin Controller
008.1420844_13 – 02/2016
Operating instructions
13
Displaying the water pressure
On the Controller RoCon HP, when it is switched on, you can
display the system pressure (water pressure) in the internal
circuit (direct heating circuit). The water pressure is available as
the first info parameter after the operating data overview
(see fig. 3-6).
The permissible range of water pressure during operation de-
pends on the Daikin Altherma EHS(X/H) and the heating system.
The set values and threshold values must only be changed by the
heating technician. If the water pressure falls below the minimum
value (set parameter value), it must be increased by topping up
the system (see installation instructions of the Daikin
Altherma EHS(X/H), chapter "Inspection and Maintenance").
The pressure limits for the safety switch-off and the set
pressure can be adjusted in the parameter settings in
level
"System "
.
Info
Overview
Water Pressure
T-HS
Water Pressure
Fig. 3-6
Info values display (e.g. system pressure)
3.4.2 Setting the operating mode
The selection of the operating mode with which the Daikin
Altherma EHS(X/H) is to operate is undertaken on the rotary
switch in the setting
"Operating Mode"
.
The selected operating mode is activated by briefly pushing the
rotary switch.
Operating Mode
Standby
Reducing
Operating Mode
Heating
Cooling
Summer
Operating Mode
Summer
Automatic 1
Automatic 2
Operating Mode
Summer
Automatic 1
Automatic 2
Fig. 3-7
Switching the operating mode
(e.g.: from "Standby" to "Automatic 1")
●
Place the rotary switch in the
"Operating Mode"
position.
An overview is displayed.
●
Select the desired operating mode with the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
Daikin Altherma EHS(X/H) operates in accordance with
the set operating mode.
The current operating mode is indicated by an appropriate
symbol in the standard display.
Operating mode Standby (Stand-by)
CAUTION!
A heating system that is not frost-pro-
tected can freeze in cold weather and be
damaged.
●
Drain the water out of the heating
system if there is a danger of frost.
●
If the heating system is not drained
and there is a risk of frost, the power
supplies must be secured and the
external main switch must remain
switched on.
In this mode, the Daikin Altherma EHS(X/H) is shifted to the
stand-by mode. The
frost-protection function
(see section 3.6.5) remains in place. In order to maintain this
function, the system must not be disconnected from the mains!
Содержание EHS157034
Страница 61: ...9 x Notes Daikin RoCon HP Daikin Controller 008 1420844_13 02 2016 Operating instructions 61 9 2 Other items ...
Страница 62: ...Operating instructions 62 Daikin RoCon HP Daikin Controller 008 1420844_13 02 2016 9 x Notes ...
Страница 64: ...008 1420844_13 02 2016 Copyright 2016 Daikin ...