08 + ERLQ004~008
Daikin Altherma - Low Temperature Split
4P313774-1 – 2012.05
Installer reference guide
90
15 Technical data
3G
3G
3G
4G
4G
4G
V 253
253 253
253
440 440
V 207
207 207
207
360 360
+ EK*Z2
kVA
-
-
-
-
(9)
(9)
+ EK*V3
kVA
(9)
(9)
(9)
(9)
(9)
(9)
+ EK*Z2
A
-
-
-
-
26 (13+13)
Ω
Ω
V
Hz
+ EK*V3
A
A
230
230
230
230
400
400
50
50
1~
3~
1~
3~
1~
3~
3 6
3
6
6
9
3V
9W
2
3
2
4
3
2
2
5G
3G
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
(9)
2
3D078754_B page 2
13
13
kW
(1) Above mentioned power supply of the hydro box is for the backup heater only. The Switch box & pump of the hydrobox are supplied via the outdoor unit. The optional domestic warm water
tank has a separate power supply.
(3) Select diameter and type according to national and local regulations
(4) For more details of the voltage range and current refer to installation manual
(5) Voltage: 230V / Maximum current: 100mA / Minimum 0,75mm²
(6) Depends on thermostat type, refer to installation manual
(7) Wire included in option *KHW*
(8) In accordance with EN/IEC 61000-3-11(*), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys(***) ≤ Zmax
(9) Equipment complying with EN/IEC 61000-3-12 (**)
(*) : European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
(**) : European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase.
(***) : System impedance
Notes
for connection with bottom plate
heater
for connection with optional FWXV*
(demand input and output signal)
for connection with M3S
for connection with M2S
for connection with A3P
for connection with R6T
for connection with R5T
for connection to optional *KHW*
model + Q2L
Power supply for optional *KHW*
domestic hot water pump
Electricity meter
type of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
type of wires
quantity of wires
quantity of wires
Preferential kWh rate power
supply
User interface
Communication cable
Wiring connections
for power supply back up heater
Maximum
Minimum
Voltage range
signal : 0,75 mm² till 1,25 mm²(max length 50 m)
power : 6,3 A note (3)
power : 2
signal : 2
0,75 mm² till 1,25 mm² ( max length 500 m )
2,5 mm²
Note (3)
Note (3)
Note (3)
Note (3)
Note (3)
Note (3)
39 (26+13)
21,7 (8,7+13)
26 (13+13)
Running Current
(backup
booster heater
(*KHW* models))
Zmax (back-up booster
heater (*KHW* models))
Minimum S
sc
Value (8)
Minimum S
sc
Value (8)
Zmax (back-up heater)
Running Current (back-up heater)
Current
Voltage
Frequency
Phase
Power supply (1)
Capacity setting
Type
Electric heater ( optional )
Note (3)
100 mA, minimum 0,75 mm²
Note (3) and (5)
Note (3) and (5)
Note (3) and (5)
Note (6)
Minimum 0,75 mm²
Note (7)
Note (7)
Note (3) and (4)
13A, note (3)
Minimum 0,75 mm² (2A in rush, 1A continuous)
Minimum 0,75 mm² (5V DC pulse detection)
20,5 (13+7,5)
16,2 (8,7+7,5)
26 (13+13)
28,1 (15,1+13)
15,1
ELECTRICAL SPECIFICATIONS
0,29
0,29
0,17
26
8,7
13